Guides · The tower

Impact windows for condos and high-rises

A condo window has to clear four checks no house window faces all at once: the association’s specification, the missile level for the unit’s height above grade, the HVHZ approval path in Miami-Dade and Broward, and a design pressure that rises with every floor. Each criterion below links its code concept, then the released lines show what is on file.

Last checked: October 19, 2026 · Part of impact windows by home type. General information, not engineering for any specific unit.

The criteria for a unit in a tower

Apply these before looking at any product. Each one is answered by a document, not by a brochure, and the explainer in the third column shows you where to look.

CriterionWhy it matters in a towerConcept and explainer
Matches the association specificationMost buildings adopt one product, color and glass, and the board checks each application first.The condo or HOA architectural rules for exterior openings. Condo and HOA approval
Missile rating for the height of the openingUnits above 30 feet need at least the small missile test; units at or below it need the large missile. One building can need both.Large missile up to 30 feet above grade, small missile above it. Large vs small missile (LMI vs SMI)
Approval path for the countyIn Miami-Dade and Broward the approval must show the HVHZ tests, usually through an NOA.High-Velocity Hurricane Zone (Miami-Dade, Broward): NOA or HVHZ-tested FL approval. HVHZ requirements
Design pressure at the openingPressure grows with height and is highest at the corners of the building, so upper and corner units often need a higher DP.Positive and negative DP from the approval, at your exact size and configuration. Window ratings explained
Terrain exposure of the siteA tower facing open water has no shelter, which raises the pressure again.Exposure category (B, C or D) and height raise the pressure an opening must resist. Design wind speed by city

Released lines with height-related data

Of the 88 lines in the instant-pricing release, 32 carry at least one fact this page can use: a missile version in the line name or on a transcribed catalog page (15 name LMI, 9 name SMI), an HVHZ statement from a catalog page (2), or a transcribed design pressure (8). Lines with none of these are not listed; that does not mean they lack a rating.

LineMissile version
Source: SmartWay pricing release (line name), or the catalog page named
HVHZ statement
Source: the catalog page named
Design pressure
Source: the catalog page named
ES Windows 500Y LMI - SINGLE HUNG
Single Hung
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows 500Y SMI - SINGLE HUNG
Single Hung
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows 600Y LMI - SINGLE HUNG
Single Hung
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows 600Y SMI - SINGLE HUNG
Single Hung
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows 2400ST LMI - SLIDING GLASS DOOR
Sliding Glass Door
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows DM-12 LMI - SLIDING GLASS DOOR
Sliding Glass Door
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-H340 LMI - SINGLE HUNG
Single Hung
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-H340 SMI - SINGLE HUNG
Single Hung
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-MX1000 - SINGLE HUNG
Single Hung
Impact categories listed: LMI and SMI; confirm the exact assembly for the project
Source: ESW MultiMax product catalog, page 4
Not transcribed: confirm in reviewPublished design load: +80 / -90 psf, LMI assembly
Source: ESW MultiMax product catalog, page 4
ES Windows ES-MX1500 - FIXED WINDOW
Picture Window
Not transcribed: confirm in reviewNot transcribed: confirm in reviewTested design load (catalog): +70/-80 psf (LMI)
Source: ESW MultiMax product catalog, page 5
ES Windows ES-MX2000 - HORIZONTAL ROLLER
Horizontal Roller
Not transcribed: confirm in reviewNot transcribed: confirm in reviewTested design load (catalog): +80/-90 psf (LMI)
Source: ESW MultiMax product catalog, page 6
ES Windows ES-P252 LMI - CASEMENT
Casement
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-P252 LMI - FIXED WINDOW
Picture Window
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-P252 LMI AWNING
Awning
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-P252 SMI - CASEMENT
Casement
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-SW340 LMI - HORIZONTAL ROLLER
Horizontal Roller
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows ES-SW340 SMI - HORIZONTAL ROLLER
Horizontal Roller
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows GW-2650 LMI
Awning
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows GW-2650 LMI - AWNING
Awning
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows GW-2650 SMI
Awning
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows GW-2650 SMI - AWNING
Awning
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows HC-200 LMI - CASEMENT
Casement
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows HR-2600 LMI - HORIZONTAL ROLLER
Horizontal Roller
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows HR-2600 SMI - HORIZONTAL ROLLER
Horizontal Roller
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows PH-3200 LMI - SLIDING GLASS DOOR
Sliding Glass Door
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows PH-4400 LMI - SINGLE HUNG
Single Hung
LMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
ES Windows PH-4400 SMI - SINGLE HUNG
Single Hung
SMI (line name)Not transcribed: confirm in reviewNot transcribed: confirm in review
Mr. Glass MG300
Horizontal Roller
Impact rating: Large and small missile; meets Florida Building Code for High Velocity Hurricane Zone
Source: Mr. Glass Product catalog 2024, page 6
Impact rating: Large and small missile; meets Florida Building Code for High Velocity Hurricane Zone
Source: Mr. Glass Product catalog 2024, page 6
Wind load: Up to 140 PSF (catalog wording "very high wind loads up to 140 PSF"; not stated per configuration or size, and not split into positive/negative design pressure)
Source: Mr. Glass Product catalog 2024, page 6
Mr. Glass MG350
Single Hung, Horizontal Roller, Picture Window
MG-350 (HR): Impact rating: LMI; meets Florida Building Code for High Velocity Hurricane Zone; the catalog lists no SMI approval for MG-350 (HR)
Source: Mr. Glass Product catalog 2024, page 7
MG-350 (HR): Impact rating: LMI; meets Florida Building Code for High Velocity Hurricane Zone; the catalog lists no SMI approval for MG-350 (HR)
Source: Mr. Glass Product catalog 2024, page 7
MG-350 (HR): Design pressure: DP = +/-65 PSF (one value for the whole page; the catalog does not state it at the maximum sizes or per configuration)
Source: Mr. Glass Product catalog 2024, page 7
ESR 1000
Single Hung
Not transcribed: confirm in reviewNot transcribed: confirm in reviewTested design load (catalog): +80/-90 psf (LMI)
Source: ESR Residential product catalog, page 6
ESR 1500
Picture Window
Not transcribed: confirm in reviewNot transcribed: confirm in reviewTested design load (catalog): +70/-90 psf (LMI)
Source: ESR Residential product catalog, page 7
ESR 2000
Horizontal Roller
Not transcribed: confirm in reviewNot transcribed: confirm in reviewTested design load (catalog): +80/-90 psf (LMI)
Source: ESR Residential product catalog, page 8

A missile version in a line name is the manufacturer’s naming, and a catalog page is a reference: neither is a project approval. The association criterion is not in this table because no catalog can answer it; your building’s specification does.

Height changes the answer twice

The first change is the missile. Under §1609.1.2 of the Florida Building Code, glazed openings within 30 feet of grade in a wind-borne debris region must pass the large missile test of ASTM E1996, and openings higher up the small missile test. Inside the High-Velocity Hurricane Zone, §1626 uses its own protocols, TAS 201 and TAS 203, with the same 30-foot line. The height is measured from grade to the opening, so a lobby, a parking podium or a sloped site moves the line by floors.

The second change is pressure. Wind speed and pressure grow with height, and the code asks for more resistance near the corners of a wall than in its middle, so an approval that suits a low mid-wall unit can fall short on a high corner. Your permit drawings state the number for each opening, and a balcony sliding door is usually the largest of them; the approval has to meet it at your exact size.

The association comes first in the schedule

In most buildings the board, or a committee it appoints, examines window replacements before a permit is pulled. The specification it adopted usually fixes the frame color, the glass tint and sometimes the product line, so neighbors see one facade. Ask the manager for that document before you price anything: a product that meets every code criterion and the wrong color is still the wrong product. The declaration of your condominium decides who is responsible for the windows and their installation, so read it or ask the manager.

Expect the application to ask for the product approval and the drawings of each opening. Our condo and HOA approval guide covers that paperwork and the limits on what a board can refuse.

How to decide for your unit

  1. Get the association’s window specification and application form.
  2. Find the height of each opening above grade, and whether the building is in Miami-Dade or Broward (HVHZ) or elsewhere. The wind speed by city table lists the HVHZ status of every city we cover.
  3. Get the design pressure for each opening from the permit drawings, or from the engineer the association or contractor uses.
  4. Narrow the released lines with the table above, then check each approval: missile level, HVHZ tests, DP at your size (see the NOA walk-through).
  5. Build the unit in the Project Builder; anything outside the release goes to specialist review.

Questions about condo and high-rise windows

What is the best impact window for a high-rise condo?
No single answer holds for every unit. The window that fits is the one whose approval covers the missile level for your height, the design pressure on your permit drawings and the HVHZ tests in Miami-Dade or Broward, in the specification your association adopted.
Do upper-floor condo windows need large missile impact glass?
The Florida Building Code applies the small missile test to glazing more than 30 feet above grade, so upper floors usually need at least small missile impact. Many approvals list both ratings. Essential facilities are an exception that keeps the large missile test above 30 feet.
Why would two units in the same building be quoted different products?
Height and position. Below the 30-foot line a unit needs the large missile rating, above it the small missile one, and a high corner unit can need a higher design pressure. It may be one series sold in two versions.
Can my condo association require a specific window?
Associations commonly adopt a specification for color, frame and glass and review each unit application. Our condo and HOA approval guide explains what a board may require and how to apply.
Does SmartWay know the design pressure my unit needs?
No. The required design pressure comes from the permit drawings, prepared for your building from its height, exposure and wall zone. SmartWay checks the product approval against that number during specialist review; the tables on this page show only what the catalogs print.

Other home types