Guides · The rules
HVHZ explained: impact window rules in Miami-Dade and Broward
The High-Velocity Hurricane Zone (HVHZ) is Miami-Dade and Broward counties, where the Florida Building Code applies its strictest wind provisions. A window there needs an approval document showing it meets the code including the HVHZ — tested under the TAS 201, 202 and 203 protocols — and, if it is your opening protection, that it is impact-resistant. “HVHZ” and “impact” are two separate lines on that document.
Last checked: October 16, 2026 · General information, not legal or engineering advice; the building department and the current approval document govern. · Español
HVHZ vs the rest of Florida
| HVHZ (Miami-Dade, Broward) | Rest of Florida | |
|---|---|---|
| Code provisions | FBC HVHZ sections, including wind loads (§1620) and impact tests (§1626) | Statewide wind provisions; opening protection in the wind-borne debris region |
| Impact test names | TAS 201 (large missile), TAS 203 (cyclic), TAS 202 (static pressure, air, water) | ASTM E1996 and ASTM E1886, among the accepted standards |
| Approval document | Miami-Dade NOA, or a Florida Product Approval whose evaluation covers HVHZ use | Florida Product Approval (FL number); an NOA also works where the approval fits |
| Basic wind speed, Risk Category II homes | Miami-Dade 175 mph, Broward 170 mph (FBC §1620) | By address, from the code wind maps |
| What to check first | The HVHZ statement and the missile impact line | The impact line and design pressure for your address |
Where the HVHZ came from
A Florida Building Commission presentation on the statewide code describes the “High Velocity Hurricane Zone (Miami-Dade and Broward Counties)” as the strong hurricane provisions adopted by South Florida in response to Hurricane Andrew, carried into the Florida Building Code. That is why the HVHZ reads less like a map and more like a set of stricter chapters that apply in two counties: higher design wind speeds, county test protocols and the Miami-Dade product control process.
In the 2023 Florida Building Code, Building, the HVHZ wind provisions list basic wind speeds by risk category for each county (§1620), and the impact provisions (§1626) require building-envelope components to pass impact tests or be protected by a device that does. Large missile testing applies up to 30 feet above grade, with a 9-pound 2×4 timber missile; small missile testing, with steel balls, applies above 30 feet. Our guide to large vs small missile impact explains the 30-foot line in detail.
TAS 201, 202 and 203 in plain language
- TAS 201 — large missile impact. The timber missile strikes the specimen. Passing alone is not enough: the specimen then goes through cyclic loading.
- TAS 203 — cyclic wind pressure. After impact, the specimen is cycled through thousands of positive and negative pressure loads to simulate a storm. It fails if it opens a crack longer than 5 inches and 1/16 inch wide through which air can pass.
- TAS 202 — static pressure, air and water. Uniform static air pressure, air infiltration and water resistance testing, and for some products forced entry. Miami-Dade notes that a failure anywhere in the TAS 202 sequence means repeating the whole sequence on a new or revised sample.
You can see all three in a real document. Miami-Dade NOA 25-0911.01, for an aluminum awning window, lists test reports for air infiltration, uniform static air pressure and water resistance under TAS 202, large missile impact under TAS 201 and cyclic wind pressure under TAS 203, and gives its missile impact rating as large and small missile impact resistant. Outside the HVHZ, the statewide equivalents are ASTM E1996 (the missile specification) and ASTM E1886 (the test method).
NOA vs Florida Product Approval
A Notice of Acceptance (NOA) is Miami-Dade County’s approval document. Miami-Dade describes it as the medium used to convey approval of a product to the building industry, providing the information and instructions needed to establish code compliance for permitting, installation and inspection. Each NOA states its approval and expiration dates, the drawing it approves and, for glazed products, the missile impact rating.
A Florida Product Approval is the statewide system run by the Florida Building Commission, searchable by FL number. Miami-Dade notes that an NOA can be used to obtain the optional state approval for categories including windows, and its permit page for windows and doors says Florida Building Commission product approvals are acceptable. In the HVHZ, what decides it is what the document says: an FL approval for HVHZ use states that the product complies with the code including the HVHZ.
SmartWay’s ratings and approvals guide walks through looking up either kind of document on the public portals, and a real FL evaluation report is read line by line in how to read a Florida Product Approval.
The trap: HVHZ is not the same as impact
A Florida engineering evaluation for a 4010A series non-impact aluminum horizontal roller (FL 23359) states that the product complies with the code including the HVHZ — and, in the same list of conditions, that it is not impact resistant and requires impact protection in wind-borne debris regions. Miami-Dade likewise issues separate NOAs for impact and non-impact glazed products. A window can be “HVHZ” and still need shutters.
So read two lines on any approval: the code statement (does it include the HVHZ?) and the missile impact line (large missile, small missile, or not impact-resistant). Then check that the configuration, size and design pressure fit your opening.
What SmartWay publishes about approvals, by brand
| Brand | Technical evidence on SmartWay | Published approval data |
|---|---|---|
| ES Windows (ESW) | Rules are tracked separately by series and configuration and remain conservative. | Catalog design loads quoted as references; no approval number published |
| Mr. Glass | Technical facts are limited to the exact configurations and sizes they prove. | Florida Product Approval numbers for 4 series, transcribed from the 2024 catalog |
| ES Residential (ESR) | Technical evidence is checked per observed point; unsupported cases remain under review. | No design pressure or approval number published |
Mr. Glass catalog approvals transcribed: MG-300 horizontal sliding window (FL #20359.1 LMI, FL #20359.2 SMI); MG-350 (HR) horizontal rolling window (FL #41890.1 LMI); MG-350 (SH) single hung (FL #41887.1 LMI); MG-350 (PW) fixed picture window (FL #41889.1 LMI). A price on SmartWay is never an approval; design pressure, approvals and egress are confirmed for the exact product during specialist review.
How to decide what your Miami-Dade or Broward project needs
- Confirm the county. Miami-Dade or Broward means HVHZ provisions. Palm Beach and the rest of Florida follow the statewide path.
- Decide what protects the opening. Impact windows, or non-impact windows plus approved shutters. The windows vs shutters guide compares the two.
- Get the document for the exact product. NOA or FL approval, current, with the HVHZ statement and the impact line you need.
- Match configuration and size. Your opening, its handing and any mullion must be inside the approval drawing. See XO, OX and XOX explained and window mullions.
- Keep the paperwork with the permit. The permits guide covers what the building department checks.
The exposure the HVHZ rules were written for
Questions about the HVHZ
Which counties are in the HVHZ?
Do I need a Miami-Dade NOA in Broward?
Is an HVHZ product automatically impact-resistant?
What are TAS 201, TAS 202 and TAS 203?
Can I use HVHZ-tested windows outside Miami-Dade and Broward?
What should be on the window after it is installed?
Sources
- Florida Building Code, Building 2023, chapter 16 (UpCodes viewer) — HVHZ wind loads §1620 and impact tests §1626.
- Florida Building Commission — Florida Building Code presentation — HVHZ (Miami-Dade and Broward) as the provisions adopted after Hurricane Andrew; product approval system.
- Miami-Dade County — TAS 201 / 202 / 203 product testing inquiries — test sequence, separate impact and non-impact NOAs.
- Miami-Dade NOA 25-0911.01 — aluminum awning window, L.M.I. — test reports, missile impact rating and labeling.
- Miami-Dade NOA 25-1201.03 — aluminum tube mullion — job-site copy requirement.
- Florida Product Approval FL 23359 — engineering evaluation — HVHZ use with no impact resistance.
- Miami-Dade County — windows, shutters and doors permits and product control brochure — NOA requirement, acceptance of state approvals.
- ASTM E1996 and ASTM E1886 — statewide missile specification and test method.
- Florida Product Approval search and Miami-Dade Product Control search.
Last checked: October 16, 2026. Codes, approvals and county procedures change; the current code, the building department and the current approval document govern.
Related comparisons: ESW vs ESR impact windows · Laminated vs insulated impact glass · Single hung vs horizontal roller vs casement · Sliding glass door vs French door · Compare ESW and Mr. Glass