Guides · The paperwork

How to read a Florida Product Approval (FL number)

A Florida Product Approval is the statewide record, under an FL number, that a window or door meets the Florida Building Code; you look it up free at floridabuilding.org and read its evaluation report for the limits. The lines that decide whether it covers your opening are the design pressure, the maximum unit size, the approved configurations, and two separate statements: whether it may be used in the HVHZ and whether it is impact resistant.

Last checked: October 24, 2026 · General information, not legal advice. The statute and your building department govern.

What the FL number is

Section 553.842 of the Florida Statutes sets up a statewide product evaluation and approval system and names the categories it covers, among them windows, exterior doors, shutters and impact protective systems. A product approved through it carries an FL number. The documents on floridabuilding.org use a consistent file pattern — the FL number, an R revision and a document code — so FL16804_R8_AE_514775A is an evaluation report filed under revision 8 of FL16804, and FL33614_R1_II_PEL-298A is a set of installation drawings under revision 1 of FL33614.

The statute lists the evidence an approval can rest on for products the code tests: a certification mark or listing from an approved certification agency, a test report from an approved laboratory, an evaluation report from an approved evaluation entity, or an evaluation report signed and sealed by a Florida professional engineer or architect. The second report used on this page states that it was prepared for statewide acceptance under Rule 61G20-3.005, method 1(a).

Looking it up in three minutes

  1. Ask the seller for the FL number of each product on the quote. A quote that cannot name one for an impact window has not specified a product.
  2. Open the Florida Product Approval search. Search by the number, or choose the manufacturer and the code version.
  3. Open the record. Note its status and the code version, then open the evaluation report and the installation instructions it lists.
  4. Read the report against your opening, using the table below. The building department checks the same record when it handles your permit.

An evaluation report, line by line

The report below is a one-page engineering evaluation for a vinyl XOX horizontal roller, FL16804 revision 8. It is not a product SmartWay sells; it is a clear, current public example of the format, and every value in the table is quoted from it.

Lines of Florida Product Approval report 514775A and how to use each one
Line on the reportWhat it saysHow to use it
Manufacturer and product lineSeries 176 HRP 424 PVB vinyl horizontal sliding window, XOXMatch the series name and configuration to the one on your quote.
ComplianceComplies with the requirements of the Florida Building CodeThe code edition matters; see the code version on the approval record.
Approval documentDrawing 08-03659 Revision A, signed and sealed by the evaluating engineerThis is the drawing the installer follows and the inspector checks.
Test reportTAS 201 / TAS 203 large missile impact, Level D, Wind Zone 4; TAS 202 at ±60.0 psf; 9.0 psf waterWhich tests the unit passed, and at what pressures.
Anchor calculationsReport 514775-1AAnchoring is part of the approved assembly, not an installer’s choice.
Limitations and conditions of use±60.0 psf; unit size 110 × 62 in; approved configuration XOX (1/4 – 1/2 – 1/4); glazed per the ASTM glass standard the report namesThe real limits. Your size, configuration and required pressure must fall inside them.
HVHZ and impact statementFor use in the HVHZ; impact resistant, no impact protection required in wind-borne debris regionsTwo separate answers: whether it may be used in Miami-Dade and Broward, and whether it needs shutters.
Certification of independenceThe engineer states no financial interest in the manufacturer or the approval processThe independence the statute requires of the evaluator.

The Limitations block is the approval

Everything above the Limitations and Conditions of Use block explains how the product was evaluated; the block itself says what you may do with it. In report 514775A that means one configuration (XOX with panel proportions of 1/4, 1/2 and 1/4), one maximum unit size (110 by 62 inches) and one design pressure (plus or minus 60 psf). An XO in the same series, or a 112-inch XOX, is outside this report.

Read the design pressure against the pressure your permit drawings require for that opening — positive and negative, row by row — and the configuration against the drawing, as in XO, OX and XOX window meaning.

HVHZ use and impact are two different answers

Report 514775A answers both explicitly: the product is for use in the HVHZ, and it is impact resistant, needing no separate impact protection in wind-borne debris regions. Not every FL approval says both. A product can carry an FL number for use outside the HVHZ only, or be approved as a non-impact unit that needs shutters. The HVHZ requirements guide explains why those questions are separate, and large vs small missile impact covers the missile level the test line names.

How long an approval lasts, and who can still say no

Section 553.842(5) says state and local approvals remain valid until the requirements of the code on which the approval is based change, and ends them sooner if the product is changed in a way that affects its code performance or the approval is revoked. That is why the record shows a code version, and why building departments ask for the approval under the code edition the permit is applied under.

A statewide approval also limits how much a local building department can add: it may not require further testing for a product used within its approval. The same section lets the building official deny a specific use in a written report showing that the application is inconsistent with the approval — a size or pressure outside the Limitations block, for example.

FL number or Miami-Dade NOA?

In Miami-Dade and Broward, products usually carry a Miami-Dade Notice of Acceptance, and the statute names Miami-Dade Product Control among the evaluation entities the statewide system accepts. The NOA has its own format, with revision dates, an expiration date and evidence pages; it is read page by page in how to read a Miami-Dade NOA. For an address outside the two HVHZ counties, the FL approval is usually the document you will meet, and shipping impact windows across Florida explains which applies where SmartWay ships material.

When you build a project in the Project Builder, the specialist check compares the approval for each product against your sizes and configuration before anything is ordered.

Questions about Florida Product Approvals

What is a Florida Product Approval number?
It is the number the statewide product approval system gives a product, written as FL followed by digits, such as FL16804, with a revision (R8) and often a sub-number for each product in the family. It is searchable on floridabuilding.org and leads to the evaluation report, test summary and installation drawings.
How do I look up an FL number?
Open the Florida Product Approval search on floridabuilding.org, enter the FL number or choose the manufacturer, and open the record. The record lists the product, its status, the code version it was approved under and the uploaded documents, including the installation instructions and the evaluation report.
Does a Florida Product Approval expire?
State law says statewide approvals remain valid until the requirements of the code on which the approval is based change, unless the product changes in a way that affects its performance or the approval is revoked. In practice, check that the approval is listed under the code version your permit is applied under.
Is a Florida Product Approval valid in Miami-Dade and Broward?
Only if it says so. The HVHZ covers Miami-Dade and Broward counties, and an FL approval states whether the product may be used there. The report read on this page says the product is for use in the HVHZ; many statewide approvals do not.
What is the difference between an FL number and a Miami-Dade NOA?
An NOA is issued by Miami-Dade County Product Control and is the document HVHZ products usually carry. An FL number comes from the statewide system. Florida law names Miami-Dade Product Control as one of the evaluation entities the statewide system accepts, so many HVHZ products hold both.

Sources

Last checked: October 24, 2026. Not legal advice; the statute and your building department govern, and the current record for your exact product is the one to read.

Window ratings explained · Miami-Dade notice of acceptance · Parts of a window · Impact window glossary