Guides · The paperwork
How to read a Florida Product Approval (FL number)
A Florida Product Approval is the statewide record, under an FL number, that a window or door meets the Florida Building Code; you look it up free at floridabuilding.org and read its evaluation report for the limits. The lines that decide whether it covers your opening are the design pressure, the maximum unit size, the approved configurations, and two separate statements: whether it may be used in the HVHZ and whether it is impact resistant.
Last checked: October 24, 2026 · General information, not legal advice. The statute and your building department govern.
What the FL number is
Section 553.842 of the Florida Statutes sets up a statewide product evaluation and approval system and names the categories it covers, among them windows, exterior doors, shutters and impact protective systems. A product approved through it carries an FL number. The documents on floridabuilding.org use a consistent file pattern — the FL number, an R revision and a document code — so FL16804_R8_AE_514775A is an evaluation report filed under revision 8 of FL16804, and FL33614_R1_II_PEL-298A is a set of installation drawings under revision 1 of FL33614.
The statute lists the evidence an approval can rest on for products the code tests: a certification mark or listing from an approved certification agency, a test report from an approved laboratory, an evaluation report from an approved evaluation entity, or an evaluation report signed and sealed by a Florida professional engineer or architect. The second report used on this page states that it was prepared for statewide acceptance under Rule 61G20-3.005, method 1(a).
Looking it up in three minutes
- Ask the seller for the FL number of each product on the quote. A quote that cannot name one for an impact window has not specified a product.
- Open the Florida Product Approval search. Search by the number, or choose the manufacturer and the code version.
- Open the record. Note its status and the code version, then open the evaluation report and the installation instructions it lists.
- Read the report against your opening, using the table below. The building department checks the same record when it handles your permit.
An evaluation report, line by line
The report below is a one-page engineering evaluation for a vinyl XOX horizontal roller, FL16804 revision 8. It is not a product SmartWay sells; it is a clear, current public example of the format, and every value in the table is quoted from it.
| Line on the report | What it says | How to use it |
|---|---|---|
| Manufacturer and product line | Series 176 HRP 424 PVB vinyl horizontal sliding window, XOX | Match the series name and configuration to the one on your quote. |
| Compliance | Complies with the requirements of the Florida Building Code | The code edition matters; see the code version on the approval record. |
| Approval document | Drawing 08-03659 Revision A, signed and sealed by the evaluating engineer | This is the drawing the installer follows and the inspector checks. |
| Test report | TAS 201 / TAS 203 large missile impact, Level D, Wind Zone 4; TAS 202 at ±60.0 psf; 9.0 psf water | Which tests the unit passed, and at what pressures. |
| Anchor calculations | Report 514775-1A | Anchoring is part of the approved assembly, not an installer’s choice. |
| Limitations and conditions of use | ±60.0 psf; unit size 110 × 62 in; approved configuration XOX (1/4 – 1/2 – 1/4); glazed per the ASTM glass standard the report names | The real limits. Your size, configuration and required pressure must fall inside them. |
| HVHZ and impact statement | For use in the HVHZ; impact resistant, no impact protection required in wind-borne debris regions | Two separate answers: whether it may be used in Miami-Dade and Broward, and whether it needs shutters. |
| Certification of independence | The engineer states no financial interest in the manufacturer or the approval process | The independence the statute requires of the evaluator. |
The Limitations block is the approval
Everything above the Limitations and Conditions of Use block explains how the product was evaluated; the block itself says what you may do with it. In report 514775A that means one configuration (XOX with panel proportions of 1/4, 1/2 and 1/4), one maximum unit size (110 by 62 inches) and one design pressure (plus or minus 60 psf). An XO in the same series, or a 112-inch XOX, is outside this report.
Read the design pressure against the pressure your permit drawings require for that opening — positive and negative, row by row — and the configuration against the drawing, as in XO, OX and XOX window meaning.
HVHZ use and impact are two different answers
Report 514775A answers both explicitly: the product is for use in the HVHZ, and it is impact resistant, needing no separate impact protection in wind-borne debris regions. Not every FL approval says both. A product can carry an FL number for use outside the HVHZ only, or be approved as a non-impact unit that needs shutters. The HVHZ requirements guide explains why those questions are separate, and large vs small missile impact covers the missile level the test line names.
How long an approval lasts, and who can still say no
Section 553.842(5) says state and local approvals remain valid until the requirements of the code on which the approval is based change, and ends them sooner if the product is changed in a way that affects its code performance or the approval is revoked. That is why the record shows a code version, and why building departments ask for the approval under the code edition the permit is applied under.
A statewide approval also limits how much a local building department can add: it may not require further testing for a product used within its approval. The same section lets the building official deny a specific use in a written report showing that the application is inconsistent with the approval — a size or pressure outside the Limitations block, for example.
FL number or Miami-Dade NOA?
In Miami-Dade and Broward, products usually carry a Miami-Dade Notice of Acceptance, and the statute names Miami-Dade Product Control among the evaluation entities the statewide system accepts. The NOA has its own format, with revision dates, an expiration date and evidence pages; it is read page by page in how to read a Miami-Dade NOA. For an address outside the two HVHZ counties, the FL approval is usually the document you will meet, and shipping impact windows across Florida explains which applies where SmartWay ships material.
When you build a project in the Project Builder, the specialist check compares the approval for each product against your sizes and configuration before anything is ordered.
Questions about Florida Product Approvals
What is a Florida Product Approval number?
How do I look up an FL number?
Does a Florida Product Approval expire?
Is a Florida Product Approval valid in Miami-Dade and Broward?
What is the difference between an FL number and a Miami-Dade NOA?
Sources
- Section 553.842, Florida Statutes — product evaluation and approval — categories, approval methods, validity until the code changes, local denial by written report, Miami-Dade Product Control as an evaluation entity.
- FL16804 R8 — engineering evaluation report 514775A — the report read line by line on this page, including its TAS 201 / 202 / 203 test summary.
- FL14608 R7 — engineering evaluation report 513168A — statewide acceptance under Rule 61G20-3.005, method 1(a).
- Florida Product Approval search — the official statewide portal.
Last checked: October 24, 2026. Not legal advice; the statute and your building department govern, and the current record for your exact product is the one to read.
Window ratings explained · Miami-Dade notice of acceptance · Parts of a window · Impact window glossary