Every word you will meet on a Florida impact window quote, approval document or permit, defined in one to three plain sentences. Configuration codes like XO and OXXO, the parts of a window and its opening, the glass, the tests behind an impact rating, and the paperwork: NOAs, FL numbers, the HVHZ, the wind mitigation form. Where SmartWay has a full guide on a term, the entry links to it.
Last checked: October 17, 2026 · General information, not engineering, legal or insurance advice for any specific property.
A
- AAMA 2603
- The entry tier of three FGIA (formerly AAMA) specifications for factory-applied organic paint on aluminum extrusions and panels. FGIA describes 2603, 2604 and 2605 as the good, better and best categories of aluminum finish. See: Impact window colors and finishes
- AAMA 2604
- The middle ("better") tier of the FGIA specifications for organic coatings on aluminum extrusions and panels. If a quote names a paint finish, the specification it meets is a fair line to compare between quotes. See: Impact windows for oceanfront homes Also: Impact window colors and finishes
- AAMA 2605
- The top ("best") tier of the FGIA specifications for organic coatings on aluminum extrusions and panels, written for long-term film integrity, weathering and appearance. Ask which specification a frame finish meets rather than relying on a color name. See: Impact windows for oceanfront homes Also: Impact window colors and finishes
- Active leaf
- On a double (French) door, the leaf that carries the lock and opens first. The other, inactive leaf is usually held by bolts at the top and bottom. See: French door basics Also: Left-hand vs right-hand doors and casements
- Air infiltration
- Air leaking through a closed window or door, measured in a laboratory under a set pressure. On Miami-Dade approvals it is one of the tests run under TAS 202. See: How impact windows work
- Anchor capacity chart
- A table on the approval drawings that shows how much load a given anchor pattern can carry, often by substrate (concrete, block, wood, metal). It is why the same window can need more anchors in one wall than another. See: How to read a Miami-Dade NOA
- Anchors
- The screws or masonry fasteners that attach a window frame to the buck or wall. Their type, diameter, embedment, edge distance and spacing come from the approval drawings, and the inspector checks them against those drawings. See: Permits and inspections
- Annealed glass
- Ordinary float glass that has not been heat-treated. Alone it breaks into large sharp pieces; in impact windows, annealed plies can be laminated together with an interlayer.
- Approval document
- The signed and sealed drawing set an NOA or Florida Product Approval refers to. It holds the real limits: sizes, design pressures, glass, anchoring and configurations. See: How to read a Miami-Dade NOA
- Association approval (condo or HOA)
- The review a condominium board or homeowners association may require before exterior windows change. Florida statute limits what a board can refuse for hurricane protection. See: Condo and HOA approval
- Authority Having Jurisdiction (AHJ)
- The building department that issues the permit and enforces the code for a property. Miami-Dade NOAs are written for use in Miami-Dade County and in other areas where the AHJ allows them. See: Permits and inspections
B
- Buck
- A frame, usually pressure-treated wood, fastened inside a masonry opening so the window can be anchored to it. A buck changes the size of the opening the window must fit, so know whether a measurement was taken to the block or to the buck. See: Rough opening vs window size Also: How to measure a sliding glass door opening
- Builder (SmartWay project builder)
- SmartWay’s tool for entering each opening: product type, configuration, exact size, glass and finish. Anything outside documented manufacturer limits goes to a specialist instead of getting a guessed answer. See: Configure it in the Builder
- Building official
- The person at the building department who enforces the code. Miami-Dade NOAs require a full copy of the NOA to be available at the job site if the building official asks for it. See: Permits and inspections
C
- Casement window
- A window hinged on one side that swings outward, usually with a crank. Hinge side is part of the order, just like the moving panel on a slider.
- Caulk (perimeter sealant)
- The sealant that closes the joint between the window frame and the wall. Where and how it is applied is part of the installation details on the approval drawings.
- Configuration
- The arrangement of fixed and operating panels in a window or door, written in letter codes such as XO, XOX or OXXO. The code is read from the outside unless a drawing says otherwise. See: Window configurations explained
- Cyclic pressure test
- After the missile impact, the specimen is put through thousands of alternating positive and negative pressure cycles to simulate gusting wind. It is TAS 203 on Miami-Dade approvals and part of ASTM E1886 on the statewide side. See: How impact windows work
D
- Daylight opening (DLO)
- The visible glass area inside the frame and sash. It is smaller than the unit size and is not the number used to order a window. See: Rough opening vs window size Also: How to measure picture and mulled windows
- Deflection
- How far a frame member or the glass bends under load. Lab tests measure it at set pressures, and the approval limits it.
- Design pressure (DP)
- The wind load an assembly is engineered to resist, in pounds per square foot, written as a positive and a negative pair. It varies with size and configuration, so the row for your exact size is the one that counts. See: Window ratings explained
- Double-hung window
- A window whose upper and lower sashes both slide vertically. A single-hung window moves only the lower sash.
E
- Egress (emergency escape opening)
- An opening large enough, low enough and easy enough to open for escape and rescue, required in sleeping rooms by section R310 of the Florida Building Code, Residential. Replacing a bedroom window with a smaller or fixed unit can break that requirement. See: Bedroom egress rules for impact windows
- Elevation drawing
- A face-on drawing of a window, door or wall. Approval drawings use elevations to show tested sizes and configurations; permit drawings use them to show each opening.
- Entry door
- A hinged exterior door, single or with sidelites. Handing (which side the hinges are on) and swing (in or out) are part of the order. See: Entry door basics
- ES Windows (ESW)
- An impact window and door manufacturer whose Miami-Dade NOAs list ES Windows, LLC in Miami, Florida, as the applicant. SmartWay configures its released lines. See: ES Windows on SmartWay
- ESR (ES Residential)
- A residential impact window line offered on SmartWay in its 1000, 1500 and 2000 series. Instant figures appear only at exact, directly observed sizes. See: ESR on SmartWay
- Evidence pages (NOA)
- The pages after page 1 of a Miami-Dade NOA, numbered E-1, E-2 and so on. They list the drawings, test reports, calculations and statements the approval relies on, revision by revision. See: How to read a Miami-Dade NOA
- Expiration date
- The date after which an NOA is no longer valid. It is printed on every page of the NOA, next to the NOA number and the approval date. See: How to read a Miami-Dade NOA
- Exposure category
- A wind-engineering term (B, C or D) describing how open the terrain is around a building. Open, coastal exposure raises the pressure an opening must resist. See: Impact windows for oceanfront homes
F
- Fixed panel (O)
- A panel that does not open. In configuration codes it is the letter O. See: Window configurations explained
- Florida Building Code (FBC)
- The statewide building code. The current edition is the 2023 Florida Building Code, 8th Edition, with separate Building and Residential volumes. See: Permits and inspections
- Florida Product Approval (FL number)
- The statewide product-approval system, searchable at floridabuilding.org, with numbers like FL12345.1. Each approval states its limits of use, including whether the evaluation covers the HVHZ. See: How to read a Florida Product Approval Also: Window ratings explained
- Forced entry test
- A lab test of whether a locked window or door resists being forced open. Miami-Dade NOAs list it among the TAS 202 tests.
- Frame
- The fixed perimeter of a window or door unit: head at the top, jambs at the sides, sill at the bottom. The sash or panels sit inside it. See: Parts of a window explained
- French door
- A pair of hinged glass door leaves that meet in the middle without a fixed post. One leaf is active and one inactive. See: French door basics
G
- Glass makeup (glass build)
- The exact layers of the glass: ply thicknesses, interlayer type and thickness, and any air space or coating. The approval covers the tested makeup; a different build is a different product. See: How impact windows work
- Glazing
- The glass in a window or door, and also the act of installing it in the sash. "Wet glazed" and "dry glazed" describe whether the glass is set with sealant or with gaskets.
- Glazing bead
- The removable strip that holds the glass in the sash or frame. On impact units its profile and attachment are part of the tested assembly.
- Grid
- Decorative bars that divide the look of the glass, also called muntins or colonial grids. Grids do not hold the glass in place and are not structural. See: What a mullion is
H
- Handing
- Which side of a unit operates or hinges. On sliders it is written in the configuration code (XO vs OX); on doors it is the hinge side and swing. See: XO vs OX sliding windows and doors Also: Left-hand vs right-hand doors and casements
- Head
- The top member of a window or door frame. See: Parts of a window explained
- Header
- The structural beam in the wall above an opening that carries the load over it. It is part of the house, not the window, although the window anchors into it.
- Heat-strengthened glass
- Glass heated and cooled under control to make it stronger than annealed glass, but less so than tempered. It breaks into larger pieces than tempered glass and can be used as plies in laminated impact glass.
- High-Velocity Hurricane Zone (HVHZ)
- The part of Florida the Building Code holds to its strictest wind and impact provisions: Miami-Dade and Broward counties. Products used there need an NOA or a Florida Product Approval whose evaluation covers the HVHZ. See: Window ratings explained
- Home hardening sales tax refund
- A Florida sales tax refund on impact-resistant windows, doors and garage doors, created in 2026 and claimed through the Department of Revenue. The guide lists who qualifies and what records to keep. See: Impact window sales tax refund
- Horizontal roller
- A window whose panels slide sideways, written XO, OX or XOX. Also called a horizontal slider. See: Horizontal roller basics Also: Horizontal roller window sizes
- Hurricane shutters
- Removable or permanent coverings (panels, accordions, roll-downs) that protect non-impact glass. They meet the opening-protection requirement only when closed. See: Impact windows vs shutters
I
- Impact protective system
- A covering such as a shutter or panel that protects a non-impact opening. ASTM E1996 covers impact protective systems alongside windows and doors. See: Impact windows vs shutters
- Impact window
- A window assembly that has passed missile-impact and cyclic-pressure testing, usually with laminated glass held in a reinforced frame. The glass may crack but is meant to stay in the opening. See: How impact windows work
- Inspection
- The building department visit that checks the installed product against the permit and the approval drawings, including anchors and sealant. See: Permits and inspections
- Insulated glass unit (IG)
- Two lites of glass separated by a spacer and sealed around the edge, with air or gas between them. In impact IG units one lite is laminated; which one is set by the tested assembly. See: How impact windows work
- Interlayer
- The plastic layer laminated between glass plies in laminated glass. PVB and ionoplast (SGP) are the common types; the interlayer is what holds broken glass in place. See: PVB vs SGP laminated glass
J
- Jamb
- Either vertical side member of a window or door frame. See: Parts of a window explained
L
- Laminated glass
- Two or more glass plies permanently joined by an interlayer. When struck it cracks but the pieces stay attached to the interlayer, which keeps the opening closed. See: How impact windows work
- Large missile impact (LMI)
- An impact test that fires a length of 2×4 lumber at the specimen. Florida’s wind mitigation form puts large-missile products in its top opening-protection level, using a 9-lb missile for windows and doors. See: Large missile vs small missile impact
- Limits of use
- The conditions an approval covers: maximum sizes, design pressures, configurations, glass, substrates and anchoring. Outside them, the product is not covered by that approval. See: How to read a Miami-Dade NOA
- Lite
- A single pane of glass. An IG unit has two lites; a laminated lite has two or more plies.
- Low-E coating
- A microscopically thin metallic coating on the glass that reduces heat transfer. It is a coating, not a tint, and its effect shows up in the NFRC U-factor and SHGC. See: Impact glass options by series
M
- Manufacturing window
- The typical factory production time for a made-to-order product. It is not a delivery date; measuring, permitting and installation scheduling sit outside it. See: How to order impact windows online
- Material-only order
- Buying the windows and doors without installation. On SmartWay the buyer confirms the sizes and arranges installation and the permit. See: Material-only orders
- Miami-Dade Product Control
- The section of Miami-Dade County’s Department of Regulatory and Economic Resources that issues NOAs and publishes them in a public search. See: How to read a Miami-Dade NOA
- Missile level
- ASTM E1996 names its impact missiles by letter. Missile A is the small-missile steel-ball test; the higher letters are lumber missiles of increasing weight or speed. See: Large missile vs small missile impact
- Mr. Glass
- A Florida impact window and door manufacturer, listed as Mr. Glass Doors & Windows Manufacturing LLC in Miami-Dade Product Control’s applicant search. SmartWay configures its released series. See: Mr. Glass on SmartWay
- Mullion (mull bar)
- The structural member that joins two separate window or door units into one assembly. On impact products it is tested and can have its own approval document. See: What a mullion is Also: How to measure picture and mulled windows
- Muntin
- A bar that divides the glass within one sash, usually for appearance; the same thing buyers call a grid. It is not a mullion. See: What a mullion is Also: Parts of a window explained
- My Safe Florida Home
- The state program that starts with a free wind mitigation inspection and, for eligible homeowners, offers grants for hardening such as opening protection. The inspection comes before the work. See: My Safe Florida Home
N
- Negative pressure
- Wind suction pulling a window outward. It is written as the minus number in a DP pair and is often the harder load, especially near wall corners. See: Window ratings explained
- NFRC label
- The National Fenestration Rating Council label that reports energy figures such as U-factor and SHGC for a specific product. NFRC’s online directory lets you look a product up by manufacturer.
- NOA number
- The identifier of an NOA, written like 26-0729.15. The public PDF uses the same digits without punctuation, and each revision gets a new number that lists the one it revises. See: How to read a Miami-Dade NOA
- Notice of Acceptance (NOA)
- Miami-Dade County’s product approval document. It names the product, the approval drawings, the impact rating and the limitations, and it expires on a printed date. See: How to read a Miami-Dade NOA
- Notice of Commencement (NOC)
- A document recorded with the county and posted at the job site before the first inspection, under Florida Statutes s. 713.13. It identifies the owner, the contractor and the property for lien purposes. See: Permits and inspections
O
- O
- In a configuration code, a fixed panel that does not open. See: Window configurations explained
- OIR-B1-1802 (wind mitigation form)
- The Uniform Mitigation Verification Inspection Form, adopted by rule by the Florida Office of Insurance Regulation. Question 7 records the weakest opening protection on the house. See: Insurance and wind mitigation
- Opening protection
- Protection of glazed openings from wind-borne debris, by impact-rated products or by approved coverings. In the wind-borne debris region the Florida Building Code requires it. See: Insurance and wind mitigation
- OX
- A two-panel slider with the fixed panel on the left and the operating panel on the right, viewed from outside. See: XO vs OX sliding windows and doors
- OXO
- Three panels with the center one operating and both sides fixed. Some drawings use it for a center-opening door or window. See: XO vs OX sliding windows and doors
- OXXO
- A four-panel sliding door with two operating center panels that part in the middle and fixed panels at each end. See: OXXO and multi-panel sliding door codes Also: XO vs OX sliding windows and doors
P
- Permanent label
- The label an NOA requires on each unit, with the manufacturer’s name or logo, the series and a Product Control statement. Impact glass also carries a permanent mark identifying it. See: How to read a Miami-Dade NOA
- Permit
- The building department authorization required to replace windows and doors in Florida. The application includes the product approval documents for every product. See: Permits and inspections
- Picture window
- A fixed window that does not open, chosen for view and light. See: Picture window basics Also: Picture window sizes
- Pocketing sliding door
- A sliding door whose panels slide into a pocket in the wall, leaving the opening clear. Approval drawings show pocket and non-pocket layouts separately. See: Impact sliding glass doors for large openings
- Positive pressure
- Wind pushing a window into the building. It is the plus number in a DP pair. See: Window ratings explained
- Professional engineer (P.E.) seal
- The signature and seal of a Florida professional engineer on approval drawings and calculations. An NOA names the engineer who prepared the drawings and the Product Control engineer who examined them. See: How to read a Miami-Dade NOA
- PVB (polyvinyl butyral)
- The most common interlayer in laminated glass: a flexible plastic film that joins the plies and holds broken glass. See: PVB vs SGP laminated glass
R
- Reinforcement
- A metal insert added inside a frame or mullion profile to raise its strength. Approval charts often tie larger sizes or higher DP to a specific reinforcement.
- Revision (NOA)
- A new NOA issued when a product, drawing or code edition changes. Page 1 says which NOA it revises, and the evidence pages keep the history. See: How to read a Miami-Dade NOA
- Risk category
- A wind-engineering classification of a building by the consequence of its failure. Most houses are Risk Category II, which sets the design wind speed used for them.
- Rough opening
- The framed or masonry hole in the wall, before the window goes in. The unit is smaller than the rough opening; the clearance comes from the approval drawings. See: Rough opening vs window size Also: How to measure a sliding glass door opening
S
- Sash
- The frame that holds the glass inside the main window frame. On a single-hung window the lower sash moves. See: Parts of a window explained
- Series
- A manufacturer’s named product line, such as a specific sliding door or single-hung model. Approvals belong to a series in a configuration and size range, not to a brand. See: How to evaluate window brands
- SGP (ionoplast interlayer)
- A stiffer interlayer than PVB, known by the trade name SentryGlas. Interlayers have approvals of their own, which window NOAs list among their evidence. See: PVB vs SGP laminated glass
- SHGC (solar heat gain)
- The share of the sun’s heat that passes through a window, from 0 to 1. Lower numbers keep more heat out, which matters in Florida.
- Shims
- Thin spacers placed between the frame and the buck to set the window plumb and level. Approval drawings limit how thick the shim space may be at the anchors.
- Signed and sealed drawings
- Drawings bearing a professional engineer’s signature and seal. The approval drawings an NOA references are signed and sealed and carry Product Control’s stamp. See: How to read a Miami-Dade NOA
- Sill
- The bottom member of a window or door frame. On sliding doors its height and profile affect water resistance. See: Parts of a window explained
- Sill riser
- A raised sill profile on a sliding glass door that helps keep water out. Because it changes the tested assembly, an NOA may list a supplemental test for it. See: How to read a Miami-Dade NOA
- Single-hung window
- A window with a fixed upper sash and a lower sash that slides up. See: Single-hung basics Also: Single hung window sizes
- Sliding glass door
- A door of two or more glass panels in a track, with at least one panel that slides. Panel layouts are written like windows: XO, OX, OXXO. See: Sliding glass door basics Also: Impact sliding glass door sizes
- Small missile impact (SMI)
- An impact test that fires small steel balls at the specimen to represent roof gravel. The codes allow small-missile products only for glazing located high above grade. See: Large missile vs small missile impact
- Spacer
- The strip that separates the two lites of an insulated glass unit and seals its edge.
- Structural test (uniform static load)
- A lab test that loads the assembly with steady air pressure in both directions. In the test behind a DP rating the unit is held at 1.5 times its design pressure. See: Window ratings explained
T
- TAS 201
- The Florida Building Code test protocol for large missile impact, used for products in the HVHZ. Miami-Dade publishes how the 2×4 missile test is run. See: Window ratings explained
- TAS 202
- The protocol for static air pressure, air infiltration, water resistance and forced entry testing of windows and doors in the HVHZ. See: Window ratings explained
- TAS 203
- The protocol for cyclic wind pressure loading after impact, at multiples of the design pressure. See: Window ratings explained
- Tempered glass
- Glass heat-treated to be several times stronger than annealed glass, which breaks into small blunt pieces. It is safety glass, but tempered glass on its own is not impact glass.
- Tint
- Color in the glass itself, such as gray or bronze, that cuts glare and some heat. Tint is part of the glass makeup, so it must match a tested option. See: Configure it in the Builder Also: Impact glass options by series
- Track
- The rails a sliding door runs in. A two-track door has panels on two planes; three- and four-track frames let more panels stack. See: Sliding glass door basics
- Transom
- A window above a door or another window, usually fixed and joined to the unit below by a horizontal mullion. See: What is a transom window Also: What a mullion is
U
- U-factor
- The rate of heat flow through a window, reported on the NFRC label. Lower numbers insulate better.
W
- Wall zone (corner zone)
- Wind-load calculations split a wall into a field and edge zones; openings near corners see higher suction. That is why two windows on the same house can need different design pressures. See: Window ratings explained
- Water infiltration (water resistance)
- Water getting past a closed window under wind-driven rain. Labs test it by spraying the unit under pressure; on Miami-Dade approvals it is part of TAS 202. See: How impact windows work
- Weep holes
- Small drainage openings in the sill that let water that gets into the frame drain back outside. Blocking them with sealant or paint defeats the design.
- Wind mitigation inspection
- An inspection that documents a home’s wind-resistance features on form OIR-B1-1802 so an insurer can apply the credits Florida law requires it to offer. See: Insurance and wind mitigation
- Wind speed (ultimate design wind speed)
- The wind speed a building’s structure is designed for at its location, in miles per hour, from the ASCE 7 maps the Florida Building Code adopts. It feeds the pressure each opening must resist.
- Wind-borne debris region
- The areas where the Florida Building Code requires glazed openings to be protected against flying debris, set by design wind speed and distance from the coast. Inside the HVHZ, separate HVHZ provisions apply. See: Window ratings explained
X
- X
- In a configuration code, a panel that operates (slides or opens). See: Window configurations explained
- XO
- A two-panel slider with the operating panel on the left and the fixed panel on the right, viewed from outside. From inside, the same unit reads OX. See: Window configurations explained
- XOX
- A three-panel slider with a fixed center and an operating panel at each end. See: Window configurations explained
- XX
- Two panels that both operate, as on a double slider. See: XO vs OX sliding windows and doors
Where these words come from
Most of this vocabulary is defined somewhere official. The Florida Building Code defines the High-Velocity Hurricane Zone and the wind-borne debris region; Miami-Dade County publishes the TAS 201, 202 and 203 test protocols behind its Notices of Acceptance; ASTM E1886 and ASTM E1996 define the impact and cyclic tests used on the statewide side; FGIA publishes AAMA 2603, AAMA 2604 and AAMA 2605 for aluminum finishes; and the Florida Office of Insurance Regulation adopted the OIR-B1-1802 wind mitigation form. The Notice of Commencement comes from Florida Statutes s. 713.13. The sources below link each one.
To see the terms in a real document, read our walk-through of how to read a Miami-Dade NOA. To put them to work on your own openings, enter each opening in the project builder: configuration, exact size, glass and finish.
Sources
- Florida Building Code, Building, 8th Edition (2023), Chapter 2 — definitions (§202), including the High-Velocity Hurricane Zone and the wind-borne debris region
- Florida Building Code, Building, 8th Edition (2023), Chapter 16 — wind loads and opening protection (§1609) and HVHZ impact testing (§1626)
- Florida Building Code, Residential, 8th Edition (2023), Chapter 3 — emergency escape and rescue openings (section R310)
- Miami-Dade County — TAS 201 / 202 / 203 test protocols and Product Control testing notes
- Miami-Dade County Product Control search — the public NOA database
- Miami-Dade NOA No. 26-0729.15 (ES Windows, LLC, Series EL400 sliding glass door) — the example document behind the NOA, evidence-page, label and revision entries
- Florida Product Approval search — the statewide FL-number database
- ASTM E1886 — test method for missile impact and cyclic pressure
- ASTM E1996 — specification for windows, doors and impact protective systems impacted by windborne debris
- FGIA — AAMA 2603, AAMA 2604 and AAMA 2605 finishes documents (good, better, best)
- Florida Office of Insurance Regulation — form OIR-B1-1802, Uniform Mitigation Verification Inspection Form (question 7, opening protection)
- Florida Statutes s. 713.13 — Notice of Commencement
- NFRC product directory — U-factor and SHGC by product
- ASCE 7 Hazard Tool — design wind speed and risk category by address
Last checked: October 17, 2026. Each link above was opened on that date. Code editions, forms and approvals change; when one does, the entry is corrected.