Guides · The vocabulary

Florida impact window glossary: 120 terms explained

Every word you will meet on a Florida impact window quote, approval document or permit, defined in one to three plain sentences. Configuration codes like XO and OXXO, the parts of a window and its opening, the glass, the tests behind an impact rating, and the paperwork: NOAs, FL numbers, the HVHZ, the wind mitigation form. Where SmartWay has a full guide on a term, the entry links to it.

Last checked: October 17, 2026 · General information, not engineering, legal or insurance advice for any specific property.

Reading tip: three groups of words do most of the work on a quote. The configuration says which panels move, the design pressure says how much wind the exact size resists, and the NOA or FL number says where that is written down. Everything else in this list explains one of those three.

A

AAMA 2603
The entry tier of three FGIA (formerly AAMA) specifications for factory-applied organic paint on aluminum extrusions and panels. FGIA describes 2603, 2604 and 2605 as the good, better and best categories of aluminum finish. See: Impact window colors and finishes
AAMA 2604
The middle ("better") tier of the FGIA specifications for organic coatings on aluminum extrusions and panels. If a quote names a paint finish, the specification it meets is a fair line to compare between quotes. See: Impact windows for oceanfront homes Also: Impact window colors and finishes
AAMA 2605
The top ("best") tier of the FGIA specifications for organic coatings on aluminum extrusions and panels, written for long-term film integrity, weathering and appearance. Ask which specification a frame finish meets rather than relying on a color name. See: Impact windows for oceanfront homes Also: Impact window colors and finishes
Active leaf
On a double (French) door, the leaf that carries the lock and opens first. The other, inactive leaf is usually held by bolts at the top and bottom. See: French door basics Also: Left-hand vs right-hand doors and casements
Air infiltration
Air leaking through a closed window or door, measured in a laboratory under a set pressure. On Miami-Dade approvals it is one of the tests run under TAS 202. See: How impact windows work
Anchor capacity chart
A table on the approval drawings that shows how much load a given anchor pattern can carry, often by substrate (concrete, block, wood, metal). It is why the same window can need more anchors in one wall than another. See: How to read a Miami-Dade NOA
Anchors
The screws or masonry fasteners that attach a window frame to the buck or wall. Their type, diameter, embedment, edge distance and spacing come from the approval drawings, and the inspector checks them against those drawings. See: Permits and inspections
Annealed glass
Ordinary float glass that has not been heat-treated. Alone it breaks into large sharp pieces; in impact windows, annealed plies can be laminated together with an interlayer.
Approval document
The signed and sealed drawing set an NOA or Florida Product Approval refers to. It holds the real limits: sizes, design pressures, glass, anchoring and configurations. See: How to read a Miami-Dade NOA
Association approval (condo or HOA)
The review a condominium board or homeowners association may require before exterior windows change. Florida statute limits what a board can refuse for hurricane protection. See: Condo and HOA approval
Authority Having Jurisdiction (AHJ)
The building department that issues the permit and enforces the code for a property. Miami-Dade NOAs are written for use in Miami-Dade County and in other areas where the AHJ allows them. See: Permits and inspections

Back to the letters

B

Buck
A frame, usually pressure-treated wood, fastened inside a masonry opening so the window can be anchored to it. A buck changes the size of the opening the window must fit, so know whether a measurement was taken to the block or to the buck. See: Rough opening vs window size Also: How to measure a sliding glass door opening
Builder (SmartWay project builder)
SmartWay’s tool for entering each opening: product type, configuration, exact size, glass and finish. Anything outside documented manufacturer limits goes to a specialist instead of getting a guessed answer. See: Configure it in the Builder
Building official
The person at the building department who enforces the code. Miami-Dade NOAs require a full copy of the NOA to be available at the job site if the building official asks for it. See: Permits and inspections

Back to the letters

C

Casement window
A window hinged on one side that swings outward, usually with a crank. Hinge side is part of the order, just like the moving panel on a slider.
Caulk (perimeter sealant)
The sealant that closes the joint between the window frame and the wall. Where and how it is applied is part of the installation details on the approval drawings.
Configuration
The arrangement of fixed and operating panels in a window or door, written in letter codes such as XO, XOX or OXXO. The code is read from the outside unless a drawing says otherwise. See: Window configurations explained
Cyclic pressure test
After the missile impact, the specimen is put through thousands of alternating positive and negative pressure cycles to simulate gusting wind. It is TAS 203 on Miami-Dade approvals and part of ASTM E1886 on the statewide side. See: How impact windows work

Back to the letters

D

Daylight opening (DLO)
The visible glass area inside the frame and sash. It is smaller than the unit size and is not the number used to order a window. See: Rough opening vs window size Also: How to measure picture and mulled windows
Deflection
How far a frame member or the glass bends under load. Lab tests measure it at set pressures, and the approval limits it.
Design pressure (DP)
The wind load an assembly is engineered to resist, in pounds per square foot, written as a positive and a negative pair. It varies with size and configuration, so the row for your exact size is the one that counts. See: Window ratings explained
Double-hung window
A window whose upper and lower sashes both slide vertically. A single-hung window moves only the lower sash.

Back to the letters

E

Egress (emergency escape opening)
An opening large enough, low enough and easy enough to open for escape and rescue, required in sleeping rooms by section R310 of the Florida Building Code, Residential. Replacing a bedroom window with a smaller or fixed unit can break that requirement. See: Bedroom egress rules for impact windows
Elevation drawing
A face-on drawing of a window, door or wall. Approval drawings use elevations to show tested sizes and configurations; permit drawings use them to show each opening.
Entry door
A hinged exterior door, single or with sidelites. Handing (which side the hinges are on) and swing (in or out) are part of the order. See: Entry door basics
ES Windows (ESW)
An impact window and door manufacturer whose Miami-Dade NOAs list ES Windows, LLC in Miami, Florida, as the applicant. SmartWay configures its released lines. See: ES Windows on SmartWay
ESR (ES Residential)
A residential impact window line offered on SmartWay in its 1000, 1500 and 2000 series. Instant figures appear only at exact, directly observed sizes. See: ESR on SmartWay
Evidence pages (NOA)
The pages after page 1 of a Miami-Dade NOA, numbered E-1, E-2 and so on. They list the drawings, test reports, calculations and statements the approval relies on, revision by revision. See: How to read a Miami-Dade NOA
Expiration date
The date after which an NOA is no longer valid. It is printed on every page of the NOA, next to the NOA number and the approval date. See: How to read a Miami-Dade NOA
Exposure category
A wind-engineering term (B, C or D) describing how open the terrain is around a building. Open, coastal exposure raises the pressure an opening must resist. See: Impact windows for oceanfront homes

Back to the letters

F

Fixed panel (O)
A panel that does not open. In configuration codes it is the letter O. See: Window configurations explained
Florida Building Code (FBC)
The statewide building code. The current edition is the 2023 Florida Building Code, 8th Edition, with separate Building and Residential volumes. See: Permits and inspections
Florida Product Approval (FL number)
The statewide product-approval system, searchable at floridabuilding.org, with numbers like FL12345.1. Each approval states its limits of use, including whether the evaluation covers the HVHZ. See: How to read a Florida Product Approval Also: Window ratings explained
Forced entry test
A lab test of whether a locked window or door resists being forced open. Miami-Dade NOAs list it among the TAS 202 tests.
Frame
The fixed perimeter of a window or door unit: head at the top, jambs at the sides, sill at the bottom. The sash or panels sit inside it. See: Parts of a window explained
French door
A pair of hinged glass door leaves that meet in the middle without a fixed post. One leaf is active and one inactive. See: French door basics

Back to the letters

G

Glass makeup (glass build)
The exact layers of the glass: ply thicknesses, interlayer type and thickness, and any air space or coating. The approval covers the tested makeup; a different build is a different product. See: How impact windows work
Glazing
The glass in a window or door, and also the act of installing it in the sash. "Wet glazed" and "dry glazed" describe whether the glass is set with sealant or with gaskets.
Glazing bead
The removable strip that holds the glass in the sash or frame. On impact units its profile and attachment are part of the tested assembly.
Grid
Decorative bars that divide the look of the glass, also called muntins or colonial grids. Grids do not hold the glass in place and are not structural. See: What a mullion is

Back to the letters

H

Handing
Which side of a unit operates or hinges. On sliders it is written in the configuration code (XO vs OX); on doors it is the hinge side and swing. See: XO vs OX sliding windows and doors Also: Left-hand vs right-hand doors and casements
The top member of a window or door frame. See: Parts of a window explained
The structural beam in the wall above an opening that carries the load over it. It is part of the house, not the window, although the window anchors into it.
Heat-strengthened glass
Glass heated and cooled under control to make it stronger than annealed glass, but less so than tempered. It breaks into larger pieces than tempered glass and can be used as plies in laminated impact glass.
High-Velocity Hurricane Zone (HVHZ)
The part of Florida the Building Code holds to its strictest wind and impact provisions: Miami-Dade and Broward counties. Products used there need an NOA or a Florida Product Approval whose evaluation covers the HVHZ. See: Window ratings explained
Home hardening sales tax refund
A Florida sales tax refund on impact-resistant windows, doors and garage doors, created in 2026 and claimed through the Department of Revenue. The guide lists who qualifies and what records to keep. See: Impact window sales tax refund
Horizontal roller
A window whose panels slide sideways, written XO, OX or XOX. Also called a horizontal slider. See: Horizontal roller basics Also: Horizontal roller window sizes
Hurricane shutters
Removable or permanent coverings (panels, accordions, roll-downs) that protect non-impact glass. They meet the opening-protection requirement only when closed. See: Impact windows vs shutters

Back to the letters

I

Impact protective system
A covering such as a shutter or panel that protects a non-impact opening. ASTM E1996 covers impact protective systems alongside windows and doors. See: Impact windows vs shutters
Impact window
A window assembly that has passed missile-impact and cyclic-pressure testing, usually with laminated glass held in a reinforced frame. The glass may crack but is meant to stay in the opening. See: How impact windows work
Inspection
The building department visit that checks the installed product against the permit and the approval drawings, including anchors and sealant. See: Permits and inspections
Insulated glass unit (IG)
Two lites of glass separated by a spacer and sealed around the edge, with air or gas between them. In impact IG units one lite is laminated; which one is set by the tested assembly. See: How impact windows work
Interlayer
The plastic layer laminated between glass plies in laminated glass. PVB and ionoplast (SGP) are the common types; the interlayer is what holds broken glass in place. See: PVB vs SGP laminated glass

Back to the letters

J

Jamb
Either vertical side member of a window or door frame. See: Parts of a window explained

Back to the letters

L

Laminated glass
Two or more glass plies permanently joined by an interlayer. When struck it cracks but the pieces stay attached to the interlayer, which keeps the opening closed. See: How impact windows work
Large missile impact (LMI)
An impact test that fires a length of 2×4 lumber at the specimen. Florida’s wind mitigation form puts large-missile products in its top opening-protection level, using a 9-lb missile for windows and doors. See: Large missile vs small missile impact
Limits of use
The conditions an approval covers: maximum sizes, design pressures, configurations, glass, substrates and anchoring. Outside them, the product is not covered by that approval. See: How to read a Miami-Dade NOA
Lite
A single pane of glass. An IG unit has two lites; a laminated lite has two or more plies.
Low-E coating
A microscopically thin metallic coating on the glass that reduces heat transfer. It is a coating, not a tint, and its effect shows up in the NFRC U-factor and SHGC. See: Impact glass options by series

Back to the letters

M

Manufacturing window
The typical factory production time for a made-to-order product. It is not a delivery date; measuring, permitting and installation scheduling sit outside it. See: How to order impact windows online
Material-only order
Buying the windows and doors without installation. On SmartWay the buyer confirms the sizes and arranges installation and the permit. See: Material-only orders
Miami-Dade Product Control
The section of Miami-Dade County’s Department of Regulatory and Economic Resources that issues NOAs and publishes them in a public search. See: How to read a Miami-Dade NOA
Missile level
ASTM E1996 names its impact missiles by letter. Missile A is the small-missile steel-ball test; the higher letters are lumber missiles of increasing weight or speed. See: Large missile vs small missile impact
Mr. Glass
A Florida impact window and door manufacturer, listed as Mr. Glass Doors & Windows Manufacturing LLC in Miami-Dade Product Control’s applicant search. SmartWay configures its released series. See: Mr. Glass on SmartWay
Mullion (mull bar)
The structural member that joins two separate window or door units into one assembly. On impact products it is tested and can have its own approval document. See: What a mullion is Also: How to measure picture and mulled windows
Muntin
A bar that divides the glass within one sash, usually for appearance; the same thing buyers call a grid. It is not a mullion. See: What a mullion is Also: Parts of a window explained
My Safe Florida Home
The state program that starts with a free wind mitigation inspection and, for eligible homeowners, offers grants for hardening such as opening protection. The inspection comes before the work. See: My Safe Florida Home

Back to the letters

N

Negative pressure
Wind suction pulling a window outward. It is written as the minus number in a DP pair and is often the harder load, especially near wall corners. See: Window ratings explained
NFRC label
The National Fenestration Rating Council label that reports energy figures such as U-factor and SHGC for a specific product. NFRC’s online directory lets you look a product up by manufacturer.
NOA number
The identifier of an NOA, written like 26-0729.15. The public PDF uses the same digits without punctuation, and each revision gets a new number that lists the one it revises. See: How to read a Miami-Dade NOA
Notice of Acceptance (NOA)
Miami-Dade County’s product approval document. It names the product, the approval drawings, the impact rating and the limitations, and it expires on a printed date. See: How to read a Miami-Dade NOA
Notice of Commencement (NOC)
A document recorded with the county and posted at the job site before the first inspection, under Florida Statutes s. 713.13. It identifies the owner, the contractor and the property for lien purposes. See: Permits and inspections

Back to the letters

O

O
In a configuration code, a fixed panel that does not open. See: Window configurations explained
OIR-B1-1802 (wind mitigation form)
The Uniform Mitigation Verification Inspection Form, adopted by rule by the Florida Office of Insurance Regulation. Question 7 records the weakest opening protection on the house. See: Insurance and wind mitigation
Opening protection
Protection of glazed openings from wind-borne debris, by impact-rated products or by approved coverings. In the wind-borne debris region the Florida Building Code requires it. See: Insurance and wind mitigation
OX
A two-panel slider with the fixed panel on the left and the operating panel on the right, viewed from outside. See: XO vs OX sliding windows and doors
OXO
Three panels with the center one operating and both sides fixed. Some drawings use it for a center-opening door or window. See: XO vs OX sliding windows and doors
OXXO
A four-panel sliding door with two operating center panels that part in the middle and fixed panels at each end. See: OXXO and multi-panel sliding door codes Also: XO vs OX sliding windows and doors

Back to the letters

P

Permanent label
The label an NOA requires on each unit, with the manufacturer’s name or logo, the series and a Product Control statement. Impact glass also carries a permanent mark identifying it. See: How to read a Miami-Dade NOA
Permit
The building department authorization required to replace windows and doors in Florida. The application includes the product approval documents for every product. See: Permits and inspections
Picture window
A fixed window that does not open, chosen for view and light. See: Picture window basics Also: Picture window sizes
Pocketing sliding door
A sliding door whose panels slide into a pocket in the wall, leaving the opening clear. Approval drawings show pocket and non-pocket layouts separately. See: Impact sliding glass doors for large openings
Positive pressure
Wind pushing a window into the building. It is the plus number in a DP pair. See: Window ratings explained
Professional engineer (P.E.) seal
The signature and seal of a Florida professional engineer on approval drawings and calculations. An NOA names the engineer who prepared the drawings and the Product Control engineer who examined them. See: How to read a Miami-Dade NOA
PVB (polyvinyl butyral)
The most common interlayer in laminated glass: a flexible plastic film that joins the plies and holds broken glass. See: PVB vs SGP laminated glass

Back to the letters

R

Reinforcement
A metal insert added inside a frame or mullion profile to raise its strength. Approval charts often tie larger sizes or higher DP to a specific reinforcement.
Revision (NOA)
A new NOA issued when a product, drawing or code edition changes. Page 1 says which NOA it revises, and the evidence pages keep the history. See: How to read a Miami-Dade NOA
Risk category
A wind-engineering classification of a building by the consequence of its failure. Most houses are Risk Category II, which sets the design wind speed used for them.
Rough opening
The framed or masonry hole in the wall, before the window goes in. The unit is smaller than the rough opening; the clearance comes from the approval drawings. See: Rough opening vs window size Also: How to measure a sliding glass door opening

Back to the letters

S

Sash
The frame that holds the glass inside the main window frame. On a single-hung window the lower sash moves. See: Parts of a window explained
Series
A manufacturer’s named product line, such as a specific sliding door or single-hung model. Approvals belong to a series in a configuration and size range, not to a brand. See: How to evaluate window brands
SGP (ionoplast interlayer)
A stiffer interlayer than PVB, known by the trade name SentryGlas. Interlayers have approvals of their own, which window NOAs list among their evidence. See: PVB vs SGP laminated glass
SHGC (solar heat gain)
The share of the sun’s heat that passes through a window, from 0 to 1. Lower numbers keep more heat out, which matters in Florida.
Shims
Thin spacers placed between the frame and the buck to set the window plumb and level. Approval drawings limit how thick the shim space may be at the anchors.
Signed and sealed drawings
Drawings bearing a professional engineer’s signature and seal. The approval drawings an NOA references are signed and sealed and carry Product Control’s stamp. See: How to read a Miami-Dade NOA
Sill
The bottom member of a window or door frame. On sliding doors its height and profile affect water resistance. See: Parts of a window explained
Sill riser
A raised sill profile on a sliding glass door that helps keep water out. Because it changes the tested assembly, an NOA may list a supplemental test for it. See: How to read a Miami-Dade NOA
Single-hung window
A window with a fixed upper sash and a lower sash that slides up. See: Single-hung basics Also: Single hung window sizes
Sliding glass door
A door of two or more glass panels in a track, with at least one panel that slides. Panel layouts are written like windows: XO, OX, OXXO. See: Sliding glass door basics Also: Impact sliding glass door sizes
Small missile impact (SMI)
An impact test that fires small steel balls at the specimen to represent roof gravel. The codes allow small-missile products only for glazing located high above grade. See: Large missile vs small missile impact
Spacer
The strip that separates the two lites of an insulated glass unit and seals its edge.
Structural test (uniform static load)
A lab test that loads the assembly with steady air pressure in both directions. In the test behind a DP rating the unit is held at 1.5 times its design pressure. See: Window ratings explained

Back to the letters

T

TAS 201
The Florida Building Code test protocol for large missile impact, used for products in the HVHZ. Miami-Dade publishes how the 2×4 missile test is run. See: Window ratings explained
TAS 202
The protocol for static air pressure, air infiltration, water resistance and forced entry testing of windows and doors in the HVHZ. See: Window ratings explained
TAS 203
The protocol for cyclic wind pressure loading after impact, at multiples of the design pressure. See: Window ratings explained
Tempered glass
Glass heat-treated to be several times stronger than annealed glass, which breaks into small blunt pieces. It is safety glass, but tempered glass on its own is not impact glass.
Tint
Color in the glass itself, such as gray or bronze, that cuts glare and some heat. Tint is part of the glass makeup, so it must match a tested option. See: Configure it in the Builder Also: Impact glass options by series
Track
The rails a sliding door runs in. A two-track door has panels on two planes; three- and four-track frames let more panels stack. See: Sliding glass door basics
Transom
A window above a door or another window, usually fixed and joined to the unit below by a horizontal mullion. See: What is a transom window Also: What a mullion is

Back to the letters

U

U-factor
The rate of heat flow through a window, reported on the NFRC label. Lower numbers insulate better.

Back to the letters

W

Wall zone (corner zone)
Wind-load calculations split a wall into a field and edge zones; openings near corners see higher suction. That is why two windows on the same house can need different design pressures. See: Window ratings explained
Water infiltration (water resistance)
Water getting past a closed window under wind-driven rain. Labs test it by spraying the unit under pressure; on Miami-Dade approvals it is part of TAS 202. See: How impact windows work
Weep holes
Small drainage openings in the sill that let water that gets into the frame drain back outside. Blocking them with sealant or paint defeats the design.
Wind mitigation inspection
An inspection that documents a home’s wind-resistance features on form OIR-B1-1802 so an insurer can apply the credits Florida law requires it to offer. See: Insurance and wind mitigation
Wind speed (ultimate design wind speed)
The wind speed a building’s structure is designed for at its location, in miles per hour, from the ASCE 7 maps the Florida Building Code adopts. It feeds the pressure each opening must resist.
Wind-borne debris region
The areas where the Florida Building Code requires glazed openings to be protected against flying debris, set by design wind speed and distance from the coast. Inside the HVHZ, separate HVHZ provisions apply. See: Window ratings explained

Back to the letters

X

X
In a configuration code, a panel that operates (slides or opens). See: Window configurations explained
XO
A two-panel slider with the operating panel on the left and the fixed panel on the right, viewed from outside. From inside, the same unit reads OX. See: Window configurations explained
XOX
A three-panel slider with a fixed center and an operating panel at each end. See: Window configurations explained
XX
Two panels that both operate, as on a double slider. See: XO vs OX sliding windows and doors

Back to the letters

Where these words come from

Most of this vocabulary is defined somewhere official. The Florida Building Code defines the High-Velocity Hurricane Zone and the wind-borne debris region; Miami-Dade County publishes the TAS 201, 202 and 203 test protocols behind its Notices of Acceptance; ASTM E1886 and ASTM E1996 define the impact and cyclic tests used on the statewide side; FGIA publishes AAMA 2603, AAMA 2604 and AAMA 2605 for aluminum finishes; and the Florida Office of Insurance Regulation adopted the OIR-B1-1802 wind mitigation form. The Notice of Commencement comes from Florida Statutes s. 713.13. The sources below link each one.

To see the terms in a real document, read our walk-through of how to read a Miami-Dade NOA. To put them to work on your own openings, enter each opening in the project builder: configuration, exact size, glass and finish.

Not legal, engineering or insurance advice. The definitions here are general. For a specific property, the official source governs: the Florida Building Code as adopted by your building department, the product’s own approval document, the statute, and your insurer’s reading of the inspection form.

Sources

Last checked: October 17, 2026. Each link above was opened on that date. Code editions, forms and approvals change; when one does, the entry is corrected.