Guides · Measuring mulled units

How to measure picture windows and mulled windows (twin and triple)

First decide whether the opening holds one unit or several joined by a mullion. Then measure the whole opening — three widths, three heights, smallest of each — and, for a mulled opening, each unit from the edge to the center of the mullion. A twin is two units and one mullion, a triple is three and two. Recording it that way, rather than as one wide window, is what keeps two quotes describing the same project.

Last checked: October 19, 2026 · General information, not engineering or installation instructions for any specific opening.

Single unit or mulled assembly?

A picture window is a fixed unit: one frame, one size. Many wide openings, though, hold two or three units side by side or stacked, tied together by a mullion. The mullion guide covers what it is; this page covers how to measure around it.

The quickest test from inside the house: follow the frame around each piece of glass. If every piece has its own complete frame and the frames meet at a bar, that bar is a mullion. If several panels sit inside one continuous outer frame — a three-panel roller, for example — it is one unit with several panels, and you measure it like any single window. Not sure? Say so and add a photo.

Schematic only: a twin opening — a fixed unit (O) and an operating unit (X) joined by one vertical mullion (solid bar). Measure W1–W3 and H1–H3 across the whole opening, then each unit to the center of the mullion. Not to scale.OXW1 topW2 middleW3 bottomH1H2H3
Schematic only: a twin opening — a fixed unit (O) and an operating unit (X) joined by one vertical mullion (solid bar). Measure W1–W3 and H1–H3 across the whole opening, then each unit to the center of the mullion. Not to scale.

Step by step

  1. Decide whether it is one unit or several. Look for a full frame member between the pieces of glass. If removing it would leave two complete windows, it is a mullion and the opening is mulled; if the glass sits inside one continuous frame, it is a single unit.
  2. Measure the whole opening. Take three widths (top, middle, bottom) and three heights (left, center, right) across the entire opening, and keep the smallest of each.
  3. Measure each unit. For a mulled opening, measure each unit’s width from the edge of the opening to the center of the mullion, and the mullion’s visible width. Record every unit’s height too.
  4. Count units and mullions. Write the assembly as units plus mullions: a twin is two units and one mullion, a triple is three units and two mullions. Note whether each mullion is vertical or horizontal.
  5. Note what you measured and take a photo. Say whether the numbers are to the existing frame, the block or the buck, and photograph the whole opening with the mullions visible.
  6. Enter each unit in the Builder. Add one opening per unit with its own product type, layout and size, give them names that show they belong together, and use each opening’s notes to say which units are joined by which mullion.

Counting units and mullions

The counting rule is simple: in one row or one column, every unit after the first adds one mullion. This table applies it to the openings people most often ask about:

OpeningExampleUnitsMullionsBuilder openings
Single picture windowOne fixed unit, one frame1—1
Twin windowTwo single hungs side by side21 vertical2
Triple windowA picture window with an operating unit on each side32 vertical3
Unit with transomA fixed transom above a unit21 horizontal2

Larger walls of glass combine both directions; sketch the opening, mark every mullion and count from the sketch.

Measuring each unit in a mulled opening

Start with the whole opening exactly as for a single window. That overall size is the one that has to fit the wall.

Then measure each unit. For units side by side, run the tape from the edge of the opening to the center of the mullion, and from the center of that mullion to the next one or to the far edge. Measure the visible width of each mullion too. For a transom window, measure from the head down to the center of the horizontal mullion. Record the height of every unit: twin units are not always the same height.

These numbers describe what you see today, not order sizes. The unit sizes that get built come from the overall opening, minus the new mullion and the installation clearances that the approval documents for the exact products allow. That split is done when the size is confirmed. For an estimate, make the assembly unambiguous: how many units, which type each is, and where the mullions are.

Fixed picture windows

A large picture window is simple to measure but the unit most likely to meet a size limit. Every fixed unit has a maximum size in its approval, and large lites often use stiffer laminated glass. The PVB vs SGP guide explains why. Measure the frame or the opening, never the visible glass (the daylight opening).

There is no standard picture window size for a made-to-order impact unit: the size is your opening, within the maximum the approval allows.

One more check before you replace a bedroom window with a picture window: a fixed unit does not open, and every bedroom needs an operable escape opening. The bedroom egress guide sets out the rule. Bedroom egress and building-code requirements are not evaluated automatically. They are checked during professional review.

Why the mullion is part of the approval

On an impact window, the mullion is a tested structural member, not trim. Miami-Dade NOA 25-1201.03, for a clipped aluminum tube mullion with and without steel reinforcement, shows what that testing looks like: its evidence pages list large missile impact, static pressure and cyclic pressure reports under TAS 201, 202 and 203, run on mullions at stated spans — for example a 108-1/2 inch span for an unreinforced 2 by 4 inch tube, and 120 inch horizontal and 74 inch vertical spans for a 2 by 6 inch tube with a steel channel. That approval expires on May 30, 2028.

The measuring lesson is the span. A vertical mullion in a twin runs the full height of the opening; a horizontal one under a transom runs the full width. A taller or wider opening means a longer span, and a longer span can call for a different profile or reinforcement. Florida’s residential code points the same way: its reference standards list AAMA 450, a rating method for mulled fenestration assemblies, under section R609.8. Which spans are allowed is a document question for the exact products.

What the Builder needs

The project builder takes openings one unit at a time. For a mulled opening, add one opening per unit:

  • Type and layout per unit. A fixed unit is Picture Window, layout “Fixed (non-operating)”; an operating unit beside it might be a Single Hung Window or a horizontal roller with its own layout.
  • Exact size per unit, in inches. Fractions are fine — 35 1/2 or 35.5 — and the Builder rounds anything finer to the nearest 1/8 inch and shows you what it stored.
  • Names that group them. “Living room — left,” “Living room — right.”
  • Notes on the joints. In each opening’s notes, say which units are joined and whether the mullion is vertical or horizontal, and give the overall opening size you measured.

If you would rather not measure, leave the measurement box unticked and the opening goes in as a measurement request. On installed projects, your measurements are a starting point and professional measurement confirms final sizes before ordering. For material-only orders, you provide the confirmed manufacturing sizes; professional measurement is not included. Mulled combinations not covered by the available documentation go to a specialist rather than being assumed. For any term on this page, see the impact window glossary.

Questions about measuring picture and mulled windows

How do I measure a twin window?
Measure the whole opening first — three widths, three heights, smallest of each — then each unit from the opening edge to the center of the mullion, plus the mullion’s visible width. Record it as two units and one vertical mullion, not as one wide window.
Is a mulled window ordered as one size or two?
As separate units joined by a mullion. Each unit has its own frame size, and the mullion has its own profile and span. How the overall opening divides into unit sizes, mullion and clearances is settled when the size is confirmed, from the approval documents for the exact products.
How do I enter a mulled window in the SmartWay Builder?
Add one opening for each unit, with its own type, layout and size — for example a picture window and two single hungs for a triple. Name them so they read as one group, and say in the notes which units are joined and whether the mullion is vertical or horizontal.
Does a big picture window need a mullion?
Not necessarily — a single fixed unit has no mullion. A mullion appears when the opening is filled by two or more units, usually because the opening is larger than one unit can be built or because an operating unit sits beside the fixed one. The maximum size of one unit comes from its approval document.
Why does the height of a mulled opening matter for the mullion?
A vertical mullion spans the full height of the opening, and mullion approvals are tested at stated spans. A taller opening means a longer span, which can call for a heavier profile or steel reinforcement. That is why the height reading matters for the mullion as well as for the windows.

Sources

Last checked: October 19, 2026. Approval documents are revised and expire; the current document for your exact products governs.

Measurement guide · Measuring a sliding glass door opening · What a mullion is · Rough opening vs window size · Picture window basics

Fixed window sizes by series: picture window sizes