Guides · The escape opening
Bedroom egress rules for impact windows in Florida
Every bedroom in a Florida house needs at least one operable escape opening with a net clear opening of 5.7 square feet (5 square feet at grade), at least 24 inches high and 20 inches wide, and its bottom no more than 44 inches above the floor. Those numbers describe the hole you can climb through when the window is open — not the window size on a quote. This guide sets out the rule from section R310 of the Florida Building Code, Residential, shows why the window type matters so much, and what to confirm before ordering.
Last checked: October 17, 2026 · Bedroom egress and building-code requirements are not evaluated automatically. They are checked during professional review.
The rule, line by line
| Requirement | What the code says | Section |
|---|---|---|
| Where | Every sleeping room, plus basements and habitable attics: at least one operable opening | R310.1 |
| Net clear area | At least 5.7 sq ft; 5 sq ft for a grade-floor opening | R310.2.1 |
| Clear height | At least 24 inches | R310.2.2 |
| Clear width | At least 20 inches | R310.2.2 |
| How it is measured | The result of normal operation of the opening | R310.2.2 |
| Sill height | Bottom of the clear opening no more than 44 inches above the floor | R310.2.3 |
| Operation | From inside, without keys, tools or special knowledge | R310.1.1 |
| Where it leads | A public way, or a yard or court that opens to one; a screen enclosure is allowed where a screen door leads away from the house | R310.1 |
| Doors | A side-hinged door or a slider may serve as the escape opening | R310.3 |
Florida Building Code, Residential, 8th Edition (2023). The 9th Edition (2026) takes effect December 31, 2026; check the edition your permit falls under.
The arithmetic that catches people
The minimum height and width do not add up to the minimum area. An opening exactly 24 inches high and 20 inches wide is 480 square inches — about 3.3 square feet, well short of 5.7. The area is 820.8 square inches, so:
- At the minimum clear height of 24 inches, the clear width must be at least 34.2 inches.
- At the minimum clear width of 20 inches, the clear height must be at least 41.0 inches.
- A grade-floor opening (720 square inches) needs 30 inches of width at 24 inches high, or 36 inches of height at 20 inches wide.
Those are clear-opening numbers. The window around them is always bigger, by the frame, the meeting rail or interlock, and the sash that does not move.
How the window type changes the clear opening
The gap between unit size and clear opening varies by series and size, so it is not something to guess. The operation type sets how much of the unit can ever open:
| Type | What opens | What it means for egress |
|---|---|---|
| Single hung | The lower sash slides up behind the fixed upper one | Clear height is only part of the unit height — the lower sash, less its frame (an unequal or oriel split changes the share); the unit must be tall for it to clear 24 inches |
| Horizontal roller (XO / OX) | One panel slides sideways | Clear width is only the moving panel, less the interlock; it suits wide, short openings |
| Roller with two vents (XOX) | Two smaller side panels | Each vent counts on its own; neither may be large enough |
| Casement | The whole sash swings out on hinges | Opens most of the frame; hinge and operator hardware still take some width |
| Picture (fixed) | Nothing | Never counts as an escape opening |
| Sliding or hinged door | One or more panels | Allowed by R310.3, measured the same way |
The single hung vs horizontal roller vs casement guide compares the three types on airflow and fit, and window configurations explained decodes XO, OX and XOX.
Why we do not print a clear opening for our products
A net clear opening comes from the manufacturer’s drawings for a specific series, configuration and size: frame depth, sash dimensions, meeting rail or interlock, hardware. The catalogs we work from give unit sizes for almost every line and do not give sash or clear-opening dimensions, so we do not compute a clear opening from them. A number derived from a unit size with an assumed deduction would look precise and could be wrong by exactly the inch that fails an inspection.
What we do instead: when you mark a bedroom opening, it is flagged for an egress check, and the clear opening is confirmed against the manufacturer’s documentation during review, before anything is ordered. Bedroom egress and building-code requirements are not evaluated automatically. They are checked during professional review.
Replacing a bedroom window
Section R310.2.6 gives replacement windows an exemption from the area, dimension and sill height minimums, but only when three conditions hold: the replacement is the manufacturer’s largest standard size that fits the existing frame or rough opening; it is the same operating style, or a style with an equal or larger opening; and it is not part of a change of occupancy. Made-to-order impact windows do not come in standard sizes in the usual sense, so ask the building department how it reads the exemption for your opening. The safe course is not to make an escape opening smaller than the one you have.
Two related rules matter in Florida. Window fall protection (R312.2.1) applies when the bottom of an operable opening is less than 24 inches above the floor and more than 72 inches above the ground outside; opening control devices are allowed, but once released they may not leave less than the required clear opening. And storm shutters may be closed over escape openings during the threat of a storm (R310.4), provided one first-floor means of escape remains. Impact glass is the opening protection, so there is no shutter to close.
Checklist before you order
- Mark every sleeping room and choose the opening that will serve as its escape.
- Measure the floor to the bottom of the current clear opening; keep it at 44 inches or less.
- Open the existing window fully and measure the clear height and width; that is the opening you should not shrink.
- Pick an operation type that suits the opening’s shape, using the table above.
- Ask for the clear opening of the exact series and size from the manufacturer’s documentation, and confirm it during review. The rough opening vs window size guide explains which measurement is which.
Egress is checked with the rest of the permit; see permits and inspections. The term is also in the impact window glossary.
Questions we actually get
What size window is required for egress in a Florida bedroom?
Can a single hung impact window be an egress window?
Is a casement better for egress than a horizontal roller?
Do replacement windows have to meet current egress sizes?
Can I have shutters or bars on an egress window?
Sources
- Florida Building Code, Residential, 8th Edition (2023), Chapter 3 — R310 emergency escape and rescue openings, R312.2 window fall protection
- UpCodes — the same 2023 Florida Residential Code chapter, readable text of R310.1 through R310.6
- Miami-Dade County — Florida Building Code 9th Edition code change notice (effective December 31, 2026)
Last checked: October 17, 2026. The R310 and R312 text was read on that date. The arithmetic on this page is computed from the code minimums, not from any product.
Sizes by type: single hung window sizes · horizontal roller window sizes