Guides · The escape opening

Bedroom egress rules for impact windows in Florida

Every bedroom in a Florida house needs at least one operable escape opening with a net clear opening of 5.7 square feet (5 square feet at grade), at least 24 inches high and 20 inches wide, and its bottom no more than 44 inches above the floor. Those numbers describe the hole you can climb through when the window is open — not the window size on a quote. This guide sets out the rule from section R310 of the Florida Building Code, Residential, shows why the window type matters so much, and what to confirm before ordering.

Last checked: October 17, 2026 · Bedroom egress and building-code requirements are not evaluated automatically. They are checked during professional review.

The rule, line by line

RequirementWhat the code saysSection
WhereEvery sleeping room, plus basements and habitable attics: at least one operable openingR310.1
Net clear areaAt least 5.7 sq ft; 5 sq ft for a grade-floor openingR310.2.1
Clear heightAt least 24 inchesR310.2.2
Clear widthAt least 20 inchesR310.2.2
How it is measuredThe result of normal operation of the openingR310.2.2
Sill heightBottom of the clear opening no more than 44 inches above the floorR310.2.3
OperationFrom inside, without keys, tools or special knowledgeR310.1.1
Where it leadsA public way, or a yard or court that opens to one; a screen enclosure is allowed where a screen door leads away from the houseR310.1
DoorsA side-hinged door or a slider may serve as the escape openingR310.3

Florida Building Code, Residential, 8th Edition (2023). The 9th Edition (2026) takes effect December 31, 2026; check the edition your permit falls under.

The arithmetic that catches people

The minimum height and width do not add up to the minimum area. An opening exactly 24 inches high and 20 inches wide is 480 square inches — about 3.3 square feet, well short of 5.7. The area is 820.8 square inches, so:

  • At the minimum clear height of 24 inches, the clear width must be at least 34.2 inches.
  • At the minimum clear width of 20 inches, the clear height must be at least 41.0 inches.
  • A grade-floor opening (720 square inches) needs 30 inches of width at 24 inches high, or 36 inches of height at 20 inches wide.

Those are clear-opening numbers. The window around them is always bigger, by the frame, the meeting rail or interlock, and the sash that does not move.

How the window type changes the clear opening

The gap between unit size and clear opening varies by series and size, so it is not something to guess. The operation type sets how much of the unit can ever open:

TypeWhat opensWhat it means for egress
Single hungThe lower sash slides up behind the fixed upper oneClear height is only part of the unit height — the lower sash, less its frame (an unequal or oriel split changes the share); the unit must be tall for it to clear 24 inches
Horizontal roller (XO / OX)One panel slides sidewaysClear width is only the moving panel, less the interlock; it suits wide, short openings
Roller with two vents (XOX)Two smaller side panelsEach vent counts on its own; neither may be large enough
CasementThe whole sash swings out on hingesOpens most of the frame; hinge and operator hardware still take some width
Picture (fixed)NothingNever counts as an escape opening
Sliding or hinged doorOne or more panelsAllowed by R310.3, measured the same way

The single hung vs horizontal roller vs casement guide compares the three types on airflow and fit, and window configurations explained decodes XO, OX and XOX.

Why we do not print a clear opening for our products

A net clear opening comes from the manufacturer’s drawings for a specific series, configuration and size: frame depth, sash dimensions, meeting rail or interlock, hardware. The catalogs we work from give unit sizes for almost every line and do not give sash or clear-opening dimensions, so we do not compute a clear opening from them. A number derived from a unit size with an assumed deduction would look precise and could be wrong by exactly the inch that fails an inspection.

What we do instead: when you mark a bedroom opening, it is flagged for an egress check, and the clear opening is confirmed against the manufacturer’s documentation during review, before anything is ordered. Bedroom egress and building-code requirements are not evaluated automatically. They are checked during professional review.

Replacing a bedroom window

Section R310.2.6 gives replacement windows an exemption from the area, dimension and sill height minimums, but only when three conditions hold: the replacement is the manufacturer’s largest standard size that fits the existing frame or rough opening; it is the same operating style, or a style with an equal or larger opening; and it is not part of a change of occupancy. Made-to-order impact windows do not come in standard sizes in the usual sense, so ask the building department how it reads the exemption for your opening. The safe course is not to make an escape opening smaller than the one you have.

Two related rules matter in Florida. Window fall protection (R312.2.1) applies when the bottom of an operable opening is less than 24 inches above the floor and more than 72 inches above the ground outside; opening control devices are allowed, but once released they may not leave less than the required clear opening. And storm shutters may be closed over escape openings during the threat of a storm (R310.4), provided one first-floor means of escape remains. Impact glass is the opening protection, so there is no shutter to close.

Checklist before you order

  1. Mark every sleeping room and choose the opening that will serve as its escape.
  2. Measure the floor to the bottom of the current clear opening; keep it at 44 inches or less.
  3. Open the existing window fully and measure the clear height and width; that is the opening you should not shrink.
  4. Pick an operation type that suits the opening’s shape, using the table above.
  5. Ask for the clear opening of the exact series and size from the manufacturer’s documentation, and confirm it during review. The rough opening vs window size guide explains which measurement is which.

Egress is checked with the rest of the permit; see permits and inspections. The term is also in the impact window glossary.

Questions we actually get

What size window is required for egress in a Florida bedroom?
Section R310 of the Florida Building Code, Residential asks for a net clear opening of at least 5.7 square feet (5 square feet for a grade-floor opening), at least 24 inches high and 20 inches wide, with the bottom of the opening no more than 44 inches above the floor. Those are opening dimensions, not the size of the window.
Can a single hung impact window be an egress window?
Yes, if its open lower sash produces the required net clear opening. Only the lower sash opens, so the window has to be tall enough for that sash alone to clear 24 inches and wide enough to reach the area. The clear opening comes from the manufacturer’s drawings for the exact size, so confirm it before ordering.
Is a casement better for egress than a horizontal roller?
At the same unit size, a casement usually opens a larger share of its frame, because the whole sash swings out, while a roller opens only its moving panel. Hinge and operator hardware still take some width, so compare the clear openings the manufacturer documents, not the unit sizes.
Do replacement windows have to meet current egress sizes?
R310.2.6 exempts a replacement window from the size, dimension and sill-height minimums when it is the manufacturer’s largest standard size that fits the existing frame or rough opening, is the same operating style or one with an equal or larger opening, and is not part of a change of occupancy. Ask the building department how it applies the exemption to a made-to-order window.
Can I have shutters or bars on an egress window?
Bars, grilles and screens are allowed only if they release from the inside without a key, tool, special knowledge or extra force. Storm shutters may be closed on escape openings during the threat of a storm, as long as one means of escape on the first floor stays usable. An impact window needs no shutter, so the opening stays operable.