Hurricane code · Coral Springs · Broward County

Hurricane window code in Coral Springs: what applies to your home

Every Coral Springs home is in the High Velocity Hurricane Zone, because the Florida Building Code places all of Broward County in it, even inland cities near the Everglades. A typical home is designed for 170 mph winds, and the city checks window retrofits under Broward's Formal Interpretation #24 using its own Form 015.1 packet.

Last checked: October 24, 2026 · General information, not engineering or legal advice. Confirm requirements for your address with the building department.

Inland near the Everglades, but still in the HVHZ

Coral Springs sits about 20 miles northwest of Fort Lauderdale, with the Everglades to the west and the Sawgrass Expressway along its northern and western edges. Many owners assume that distance from the ocean means lighter window rules. It does not.

The 2023 Florida Building Code (8th Edition), in effect since December 31, 2023, defines the High Velocity Hurricane Zone (HVHZ) as Broward and Dade counties. There is no inland carve-out. A home in ZIP 33076 by the Sawgrass gets the same HVHZ provisions as a beachfront Broward home.

Wilma's eye passed over Coral Springs

On October 24, 2005, Hurricane Wilma's eye passed directly over the city. It was the most powerful storm to strike Coral Springs since the city was incorporated. Associated Press coverage reported many roofs severely damaged in Coral Springs, and a man in the city was killed when a tree fell on him. The city later estimated its tree canopy fell by about one third after the 2004 and 2005 storms.

In 2017, Hurricane Irma brought tornado warnings and power outages of up to a week in parts of the city. For an inland home, wind and wind-borne debris, not storm surge, are the main threat to windows and doors.

A 1980s city: which code era built your home?

Coral Springs was chartered on July 10, 1963 as a master-planned city, and most of it was built in a short window. Census estimates for 2024 count 47,327 housing units with a median year built of 1988. The 1980s alone account for nearly a third of all homes.

That matters because South Florida's hurricane rules changed in steps. After Hurricane Andrew in 1992, an enhanced South Florida Building Code with hurricane mitigation provisions was adopted for Broward and Dade counties in 1994. The first statewide Florida Building Code followed in 2002. About 79% of Coral Springs housing units were built before 2000, so most original windows here predate today's rules.

  • 1990s or 2000s home: the original permit date decides the code era.
  • Any age: a replacement window must meet the code in force when you apply for the permit.
Coral Springs housing units by decade built (ACS 2024 1-year, table B25034) and the code era they fall in
Decade builtApprox. unitsShareCode era
1970s9,45820.0%Before the 1994 enhanced South Florida code
1980s15,06031.8%Before the 1994 enhanced South Florida code
1990s10,06321.3%Straddles the 1994 enhanced code
2000–20099,11819.3%Straddles the 2002 statewide Florida Building Code
2010 or later1,0282.2%Florida Building Code era

170 mph, and what it means for each opening

Inside the HVHZ, FBC 2023 Section 1620.2 sets one countywide design wind speed (a 3-second gust) for all of Broward. Most homes are Risk Category II, so a typical Coral Springs house is designed for 170 mph.

Each window also needs a design pressure, in pounds per square foot (psf), based on roof height, opening size and wall position. Openings near a corner or wall end (Zone 5) see more suction than mid-wall openings (Zone 4). The Broward voluntary wind load chart (ASCE 7-22, valid only up to a 30-foot mean roof height) lists, for a 10 sq ft opening at a 15-foot roof height, +38.1 psf, -41.4 psf in Zone 4 and -51.0 psf in Zone 5. At 30 feet: +43.9, -47.6 and -58.8 psf.

Section 1626.2 applies the large-missile test (TAS 201 and TAS 203) to assemblies up to 30 feet high: a 9-pound 2x4 striking at 50 feet per second, then cyclic pressure loading of the glazing.

Broward County design wind speed by risk category (FBC 2023 Section 1620.2)
Risk categoryDesign wind speed (3-second gust)
I156 mph
II (typical home)170 mph
III180 mph
IV (essential facilities)185 mph

Product approval: what the Coral Springs packet asks for

Every window and door needs a product approval that covers its size and design pressure. Florida Statute 553.842 lists the Miami-Dade Product Control Division among the evaluation entities the Florida Building Commission approves, and says a statewide approval bars extra local testing when the product is used within its conditions.

Coral Springs' Form 015.1 asks for "NOA (Notice of Acceptance)/Product Approvals" with sizes and pressures highlighted and the opening ID at each column. Confirm with the department which approval type it accepts for your product before you buy.

Broward's FI #24: the rulebook for a Coral Springs retrofit

Broward County's Board of Rules and Appeals (BORA) Formal Interpretation #24 was approved October 12, 2023 and reissued January 9, 2025. It covers retrofit of windows, doors, garage doors and shutters on detached one- and two-family homes and townhouses with a common roof height under 30 feet. That describes most single-family homes in Coral Springs, and the city's Form 015.1 (revised February 20, 2025) tells applicants to review it before they submit.

  • Design pressure for each opening can be shown three ways: a signed and sealed site-specific plan by a Florida P.E. or architect; an unsealed site plan plus a signed and sealed worst-case pressure chart; or an unsealed site plan using the Broward voluntary wind load chart.
  • Buildings over 30 feet need a sealed site-specific design. Generic charts are not accepted above 30 feet.
  • A Florida P.E. or architect may change the buck or fasteners shown in a product's Notice of Acceptance, but only with a signed and sealed letter or drawing.

How a window permit moves through the Coral Springs Building Department

The city's hurricane recovery permitting guide lists non-like-for-like window and door replacement as work that needs a permit. Replacing glass in existing approved frames, with no frame damage, does not.

  1. Sketch and label every opening. An ink floor-plan sketch labels each opening with a letter or number. Stacked glass in one opening is labeled bottom to top (A, A1, A2).
  2. Complete the Broward retrofit schedule. Per opening: approval number and rating, required design pressure, width x height and area, wall zone (4 or 5), impact glazing, existing shutters, and whether new mullion tubes are needed.
  3. Assemble the packet. Add the highlighted approvals, a Broward County Uniform Building Permit Application, a sealed detail if any opening is altered, and the Owner/Builder Affidavit Packet (Form 029.0) if the owner applies. Paper submittals need two sets.
  4. Submit through eTRAKiT. Use etrakit.coralsprings.gov. Digitally signed and sealed documents must be uploaded there, not walked in. In person, use the One-Stop Shop at City Hall, 9500 West Sample Road, or the 24/7 parking garage drop box.
  5. Record the Notice of Commencement when required. Under Florida Statute 713.135, contracts above the statutory threshold need a recorded Notice of Commencement filed and posted on site before the first inspection.
  6. Schedule inspections online. Since February 1, 2025, inspections are not booked by phone and have no set times. Schedule in eTRAKiT; structural inspections get two-hour windows. Cancel by calling 954-344-1025 before 8 a.m. or a re-inspection fee may apply.

Planned-city appearance rules and HOAs

Coral Springs' strict appearance rules date from its planned-city start: ordinances restrict exterior paint colors, roofing materials, signs and landscaping. We found no city rule requiring design review of window style or frame color on a single-family home, and no historic districts. Ask the city if you are changing an opening's size or look.

Many neighborhoods, such as Turtle Run and the gated Fairways at Eagle Trace, have associations that may set rules on frame color, tint or muntins. Get written approval before the permit packet is final.

Condos, townhouses and taller buildings

About 27.4% of Coral Springs housing units are in buildings with five or more units, and 9.0% are townhouses. Those owners face different rules.

  • Townhouses under a 30-foot roof height fall under FI #24, like detached homes.
  • Buildings over 30 feet need a sealed site-specific design for every retrofit opening.
  • Florida Statute 553.899 requires milestone inspections of condo and co-op buildings three or more habitable stories tall. Broward's Building Safety Inspection Program (BORA Policy #05-05) inspects at 25 years from the certificate of occupancy, then every 10 years; fee simple townhouses are exempt. Required repairs are generally due within 180 days, with permits.

Flood zone: ask the city, not a map guess

Coral Springs is inland, so window decisions here are mostly about wind. Flood zone still affects some projects. The city takes part in FEMA's Community Rating System, and its Engineering Department (954-345-2160) gives property-specific flood map details, including FIRM panel, flood zone and base flood elevation, through a Flood Information Request Form.

What to have ready before you ask for a written quote

You can send your measurements to SmartWay at (754) 303-7130 for a written quote. The Coral Springs Building Department Customer Care Call Center is 954-344-1025, or email buildingpermits@coralsprings.gov.

  • Year built and, for 1990s and 2000s homes, the original permit date.
  • Mean roof height, which decides whether the Broward chart can be used.
  • Width x height of each opening, noting which sit near a wall corner (Zone 5).
  • Doors and sliders counted separately, plus any openings you want to resize.
  • Your association's written window rules, if you have an HOA or condo board.
  • After installation, a wind mitigation inspection on form OIR-B1-1802 can document the new opening protection for your insurer.

Coral Springs questions

Is Coral Springs in the High Velocity Hurricane Zone even though it is inland?
Yes. The 2023 Florida Building Code defines the HVHZ as Broward and Dade counties, with no inland exception. Coral Springs is in Broward, so HVHZ rules apply city-wide, from homes near the Sawgrass Expressway to neighborhoods on the city's eastern edge by Coconut Creek.
What design wind speed applies to a house in Coral Springs?
FBC 2023 Section 1620.2 sets one countywide value for Broward. A typical home is Risk Category II and is designed for a 170 mph 3-second gust. Essential facilities in Risk Category IV use 185 mph. Each window then needs its own design pressure based on roof height, size and wall zone.
Do I need a permit to replace windows in Coral Springs?
The city's hurricane recovery permitting guide lists non-like-for-like window and door replacement as permitted work. Replacing only the glass in existing approved frames with no frame damage does not need a permit. Window and door retrofits use the city's Form 015.1 submittal packet and are filed through eTRAKiT.
What is BORA Formal Interpretation #24 and why does Coral Springs use it?
It is Broward County's interpretation for retrofitting windows, doors, garage doors and shutters on one- and two-family homes and townhouses under 30 feet. Coral Springs' Form 015.1 tells applicants to review it before submitting. It sets the three accepted ways to document each opening's design pressure.
My Coral Springs home was built in the 1980s. Are the original windows up to code?
Likely not to current rules. The 1980s are the city's biggest building decade, and those homes predate Broward's enhanced 1994 South Florida code and the 2002 statewide code. Any replacement window must meet the code in force when the permit is applied for, including HVHZ impact testing.
How are window inspections scheduled in Coral Springs?
Online only. Since February 1, 2025, the Building Department no longer books inspections by phone or gives set times. You schedule in eTRAKiT with a Public Account or contractor login. Structural inspections get two-hour windows, and cancellations must be called in to 954-344-1025 before 8 a.m.