Hurricane code · Lighthouse Point · Broward County

Which hurricane window code applies to a home in Lighthouse Point?

Lighthouse Point is in Broward County's High-Velocity Hurricane Zone, so replacing a window or door takes a city permit and a Miami-Dade NOA or Florida Product Approval for each product. Permits go through the city's Building & Zoning Department at 3701 NE 22 Avenue. The typical home here dates to 1968, before modern wind codes.

Last checked: November 3, 2026 · General information, not engineering or legal advice. Confirm requirements for your address with the building department.

A canal city built in the 1950s and 1960s

Lighthouse Point became a town on June 13, 1956 and a city on June 11, 1957. It is named for the Hillsboro Lighthouse at the Hillsboro Inlet. Most of the city sits on canals dug in the 1950s and 1960s, about 18 miles of them, which connect to the Intracoastal Waterway and through the inlet to the Atlantic.

That history shapes your windows. The city says 80% of its residences are single-family homes, many fronting the waterways, and that more than 95% of the city is developed. So the typical job here is an older house on a lot with open water on one side.

HVHZ: the rule set that covers the whole city

Broward and Miami-Dade counties together form the High-Velocity Hurricane Zone in the Florida Building Code, the strictest wind section of the state code. Lighthouse Point is in Broward, so the HVHZ applies to every lot in the city. The edition in force is the Florida Building Code, 8th Edition (2023), effective December 31, 2023.

The city's own paperwork shows this. Its Roof Permit Requirements sheet says hurricane mitigation retrofits need an affidavit along with the High Velocity Hurricane Zone Uniform permit application form. If you are changing roofs and windows together, expect that same HVHZ language on your submission.

For wind speed, the 2023 Florida Building Code sets one figure for all of Broward. Section 1620.2 fixes it at 170 mph, a 3-second gust, for Risk Category II buildings such as most homes. Lighthouse Point is in the HVHZ, so this fixed figure applies, not a reading from the ASCE wind map.

The Lighthouse Point permit office, step by step

Window work is its own permit category here. The city's Permits page lists "Window - Repair, replace or new" and "Window - Remove and fill in opening." Swapping old glass for impact glass in the same opening is a permit, not a repair you can skip.

The city has no window checklist of its own that we could find, so confirm the submittal list with the department before you apply.

  1. Know where to go. City of Lighthouse Point Building & Zoning Department, 3701 NE 22 Avenue, Lighthouse Point, FL 33064. Open Monday through Friday, 8:00 am to 4:00 pm. Office phone 954-943-6509.
  2. Apply through the portal. The city's Permit Status page says applications can be submitted through the Lighthouse Point Building Department Public Portal, where you can also see application status and inspection results. Broward County's ePermits OneStop is also available, and the county says every Broward municipality takes part.
  3. Attach the product approvals. Broward building departments expect a current Miami-Dade Notice of Acceptance or Florida Product Approval for each window, door and shutter, with the matching sizes and ratings marked on the document.
  4. Add the Notice of Commencement if required. In Broward a recorded Notice of Commencement is needed once the contract passes the state threshold. A copy can go with the application or stay on site for the first inspection.
  5. Book inspections by 3:00 pm. Call the inspection line, 954-784-3449, by 3:00 pm to be scheduled for the next day or the earliest available slot.

Neighborhoods and ZIP codes in Lighthouse Point

The city uses ZIP 33064 for street delivery and 33074 for PO boxes. These neighborhood names come from real-estate sources, not from the city, so use them as a guide and check your own lot.

Lighthouse Point areas and what to expect for windows
AreaZIPWhat it means for windows
Venetian Isles33064Waterfront and deepwater lots. Large glass facing the water is common, so wind pressure and salt air both matter.
Coral Key Villas / Coral Key Harbor33064Grouped as one area by NeighborhoodScout, with a Coral Key Harbor subdivision also listed. Check whether an association checks exterior changes.
Federal Highway (US 1) corridor33064Treated as a separate area from the canal streets to the east. Condo listings appear here, including one at 4500 N Federal Highway.
Other canal-front streets33064 / 33074Same HVHZ, same permit office. The age of the house decides most of the work.

Your home's age decides the starting point

The median year a home was built in Lighthouse Point is 1968, based on 2023 ACS data reported by city-stats.com, across about 6,355 housing units. NeighborhoodScout puts about 57% of the housing in the 1940s through 1960s, about 32% between 1970 and 1999, and about 11% in 2000 or later. These are third-party figures.

  • Built before 1994: opening protection was not designed to today's HVHZ standard. Original windows and shutters are the ones to look at first.
  • Built 1994 to 2002: the South Florida Building Code era. Better than earlier, but product ratings and age of the units still deserve a check.
  • Built after 2002: Florida Building Code era. Many already have tested openings, so confirm approval numbers rather than assume.

What a single-family retrofit submission contains

Broward's Board of Rules and Appeals Formal Interpretation #24 covers retrofit of windows, doors, garage doors and shutters on detached one- and two-family homes and townhouses with roof height under 30 feet. Each opening needs a design pressure from one of three paths:

A signed-and-sealed site-specific plan; an unsealed plan with a sealed worst-case pressure chart; or an unsealed plan using the Broward County Fenestration Voluntary Wind Load Chart. That chart is based on ASCE 7-22 and gives wall pressures by roof height, wall zone (4 is the field of the wall, 5 is near corners) and opening area.

Most ranch homes in the city fit under the 30-foot line. Above it, a Florida engineer or architect must sign and seal the design loads.

The county's Uniform Retrofit Window & Door Schedule, BORA Policy 20-01, lists each opening with its product approval number, pressures, size and wall zone. Measure every opening before you ask for a quote.

Can I pull the permit myself?

The city publishes its own Owner/Builder disclosure statement under Florida Statute 489.103(7). A homeowner who applies must complete and notarize the Owner Builder Affidavit. By taking the permit, the owner states they know the Florida Building Code, the Lighthouse Point Zoning Code, and the order and types of inspections required.

Salt air, docks and flood maps

Canal living brings its own paperwork. The Building Department publishes a separate Permit Application Checklist for Docks & Seawalls, and Broward County's Environmental Resource License covers in-water work. Neither is about windows.

The city's code defines floodplains as areas mapped as A Zone or V Zone on FEMA flood maps, which includes Zone AE. We could not confirm what share of the city sits in those zones. The city's Flood Information page links to the FEMA map resources, so look up your own address there.

Condos, associations and the 40-year question

Broward's Building Safety Inspection Program applies to buildings 25 years or older, with re-inspection every 10 years. One- to four-family dwellings of three or fewer stories, fee-simple townhouses and buildings under 3,500 square feet are exempt. That covers most Lighthouse Point houses.

Florida Statute 553.899 requires milestone inspections of condo and co-op buildings three or more stories tall by December 31 of the year the building turns 30, then every 10 years. A local building official may move that to 25 years for reasons such as nearness to salt water.

If you own a unit on the US 1 corridor, ask your association first. We did not find a city rule on association review of windows, so that answer comes from your documents.

What the nearest official stations recorded

We found no Lighthouse Point wind readings for past storms, so we use the next station south. In Hurricane Wilma on October 24, 2005, the National Weather Service recorded Pompano Beach at 83 mph sustained with a 98 mph peak gust, though the records are incomplete after instrument failure. The Sun Sentinel's Wilma damage map for Broward includes Lighthouse Point.

Lighthouse Point questions

Do I need a permit to replace windows in Lighthouse Point?
Yes. The city's Permits page lists window repair, replacement and new windows as permit categories, plus a separate one for filling in an opening. Apply through the Building & Zoning Department at 3701 NE 22 Avenue or its online portal, and attach the product approval for each window.
Is Lighthouse Point in the HVHZ?
Yes. Broward County is part of Florida's High-Velocity Hurricane Zone, and the city's own roof sheet asks for the HVHZ Uniform permit application on hurricane retrofits. That means each product needs a Miami-Dade NOA or Florida Product Approval.
What wind speed are windows designed for in Lighthouse Point?
Broward's figure is 170 mph, a 3-second gust, for Risk Category II buildings, set by Section 1620.2 of the 2023 Florida Building Code. In the HVHZ that number does not come from the ASCE map. The exact design pressure for each opening comes from an engineer's plan, a sealed worst-case chart, or the Broward Fenestration Wind Load Chart, depending on your submission.
Can I use shutters instead of impact windows in Lighthouse Point?
Code-approved shutters can protect openings, but they also need a valid NOA or Florida approval and a permit. The Broward retrofit schedule has columns for existing and new shutters. Ask the building department which protection your project can use.
Does my Lighthouse Point condo need association approval?
Usually your governing documents decide, not the city. We found no city rule on association review. Ask your board or manager for the written exterior-change process before ordering, and expect the permit to need that approval letter.
Does the 40-year recertification apply to my Lighthouse Point house?
Almost certainly not. Broward's inspection program exempts one- to four-family dwellings of three or fewer stories. State milestone inspections apply to condo and co-op buildings of three or more stories, so only a few US 1 corridor buildings would be affected.