Hurricane code · Sea Ranch Lakes · Broward County

Hurricane Window Code in the Village of Sea Ranch Lakes

Sea Ranch Lakes is its own village, so window permits go to the Village Clerk, not Lauderdale-by-the-Sea or Fort Lauderdale. The home is in Broward's High-Velocity Hurricane Zone and a typical house is designed for 170 mph. The village code also adds a design comment from a Beach Club citizen board.

Last checked: November 18, 2026 · General information, not engineering or legal advice. Confirm requirements for your address with the building department.

Why does a Sea Ranch Lakes window job have its own permit path?

Because the village is a separate town. Sea Ranch Lakes incorporated in 1959. Its land development code describes about 91.4 acres, 210 platted home lots, one shopping center and one beachfront recreation parcel. It is built out, and the code says most applications it sees are for remodelling.

The village sits on A1A and falls inside the limits of Lauderdale-by-the-Sea, with Fort Lauderdale across the Intracoastal to the west. Many owners use a Fort Lauderdale 33308 mailing address. None of that changes who issues the permit. If the lot is inside the village line, the Village of Sea Ranch Lakes handles it.

The village is busy for its size. Its utilization report for October 2024 through September 2025 lists 205 building permit applications and 682 inspections and reinspections, all done without a private provider.

How does a window application move through the village?

Article IX of the village Land Development Code lays out four stops. The village uses planning help on an as-needed consultant basis, so expect a small office, not a large building department.

  1. Village Clerk. The Clerk is the named party for all inquiries and development applications. The village posts the Broward County Uniform Building Permit Application and asks you to print it and send it by email or fax. The form asks for your flood zone and base flood elevation.
  2. Village Building Inspector. Plans sent to the Clerk go to the Village Building Inspector, who checks them against the Florida Building Code and the village Land Development Code. For windows, that means product approvals, opening sizes and design pressures.
  3. Citizen advisory board. A board made up of Beach Club members looks at the application and comments on design and aesthetics. This is the step most other towns do not have.
  4. Village Council and permit. The code gives the Village Council the authority to approve the application. The Clerk then issues the building permit as a ministerial act. Appeals go to the Board of Adjustment within 30 days.

How is this different from Lauderdale-by-the-Sea next door?

The two towns touch, share A1A and share a beach, but they run separate permit systems. Our Lauderdale-by-the-Sea guide covers that town. Here is how the two compare for a window job.

Sea Ranch Lakes and Lauderdale-by-the-Sea, side by side
QuestionVillage of Sea Ranch LakesLauderdale-by-the-Sea
Who takes the applicationVillage Clerk, form sent by email or faxTown Building Division with a contracted reviewer, filed online
Design step in the codeBeach Club citizen board comments on design and aestheticsNo such board in the town permit steps; condo associations may have their own rules
Who approvesVillage Council has approval authority; Clerk issues permitBuilding Division process
Housing typeSingle-family only, one house per lotMix of houses, condos and towers
Sea Ranch Club condosNot in the villageInside the town

Do the gate and private roads matter for a window project?

They matter for planning, not for the code. The village comprehensive plan says every road in the village is private except 0.06 acres of State Road A1A. Public sources say the Sea Ranch Beach Club owns the roads, parks and lakes, and the village police can turn non-residents away at the main gate.

So every delivery truck, inspector and worker needs to get through the gate. Ask the village office how vendors are cleared before you set dates. The village office is at 1 Gatehouse Road, phone (954) 943-8862.

Land use rules also help explain what you will find inside. The code allows one detached single-family house per lot, caps height at 35 feet, and says garage doors may not open straight onto a street. Only three lots were vacant when the village updated its coastal plan in 2020.

What wind speed and product approval apply in Sea Ranch Lakes?

Broward County is one of two counties in the Florida Building Code's High-Velocity Hurricane Zone (HVHZ). Section 1620.2 sets Broward's design wind speed at 170 mph for typical homes (Risk Category II). There is no lower number for a gated village.

In the HVHZ, windows and doors must pass the large-missile impact and cyclic pressure tests. A Miami-Dade Notice of Acceptance (NOA) is the most common way a product shows that. Ask the Village Building Inspector which approvals the village accepts, and make sure each NOA-listed product covers the size and design pressure of the opening it fills.

  • The 35-foot height cap means most houses are low. A home with a roof height under 30 feet may use the Broward County Fenestration Voluntary Wind Load Chart for design pressures.
  • Taller two-story homes, corner units and large glass walls facing the lakes may need pressures from a Florida engineer.
  • The Florida Building Code 9th Edition is scheduled for December 31, 2026. A permit applied for after that date may fall under the new edition.

Which flood zone is a Sea Ranch Lakes home in?

It depends on which side of the village you are on. We sampled FEMA's National Flood Hazard Layer at points inside the village line on November 18, 2026. The west side, around the lakes and the Intracoastal, came back Zone AE. The center near the gate came back Zone X. The beach parcel east of A1A came back Zone VE.

The village plan adds detail. It counts 28 single-family lots on about 2,600 feet of bulkheaded Intracoastal shoreline, plus homes on the two manmade lakes, Lake Seneca and Lake Cayuga. It says a Category 1 storm surge causes little flooding overall, with modest impact on the Intracoastal edge and some ponding on northern Saranac Road.

FEMA flood zones at sampled Sea Ranch Lakes points (NFHL, checked 2026-11-18)
Sampled spotFlood zoneBase flood elevation
Cayuga Road and lake-side lots on the west sideAE (coastal floodplain)6 ft
Points near the Intracoastal on the northwest sideAE (coastal floodplain)7 ft
Gatehouse Road and the center near A1AX (0.2% annual chance, coastal)Not applicable
Beach parcel east of A1AVE (coastal high hazard)11 ft

Which village rules touch windows and shutters?

We found no village rule that names a window style, frame color or shutter type. The rules that do apply are about upkeep, appearance and fees.

  • Code section 5.04.02 says every single-family home must have windows and doors in good working order, with no boards and no broken or missing glass.
  • The same section bars any condition that hurts the look of the village, and asks owners to inspect their property each year before hurricane season.
  • Section 1.10.00 tells owners to read the Sea Ranch Lakes restrictive covenants before regulated work. Check yours along with the citizen board's design comment.
  • The village sets its own building fees. Ordinance 2023-01 lets the Village Council set them by resolution, and Resolution 2024-10 added cost recovery. Ask the Clerk for the current schedule.
  • Under that ordinance, starting work before a permit doubles the fees, failed inspections bring reinspection fees, and fees are not refundable.

How old are the houses, and why does it matter?

Most of the village was built out decades ago. Third-party listing data puts the median year built near 1963. We could not confirm that number with the Broward County Property Appraiser, so check your own parcel record.

Any house that old was built long before today's HVHZ impact rules. Original openings were not tested for large-missile impact. Many homes have been remodeled since, so the real question is what was installed in each opening and when. Old permits on file with the village can help answer that.

What should you gather before asking for a written quote?

  • Confirm the lot is inside the Village of Sea Ranch Lakes, not Lauderdale-by-the-Sea, even with a Fort Lauderdale mailing address.
  • Your flood zone and base flood elevation; the village permit form asks for both.
  • Year built from your Property Appraiser record and any past window or shutter permits.
  • Width, height and type of each opening, with photos of lake-facing or Intracoastal-facing glass.
  • Your restrictive covenants and any notes from the Beach Club citizen board.
  • After the job, a wind mitigation inspection on form OIR-B1-1802 can document the new opening protection for your insurer.
  • Questions? Call (754) 303-7130 or send your measurements for a written quote.

Sea Ranch Lakes questions

Who issues window permits in Sea Ranch Lakes?
The Village of Sea Ranch Lakes. Its code names the Village Clerk as the party who receives applications and issues the building permit. The Village Building Inspector checks the plans, a Beach Club citizen board comments on design, and the Village Council has approval authority. Lauderdale-by-the-Sea and Fort Lauderdale do not handle village lots.
My address says Fort Lauderdale 33308. Am I in Sea Ranch Lakes?
Maybe. Homes in the village often use a Fort Lauderdale mailing address, and so do homes in Lauderdale-by-the-Sea and Fort Lauderdale itself. The mailing city does not decide the permit office. Check your parcel's city on the Broward County Property Appraiser record before you file anything.
Does the Beach Club have to approve my new windows?
The village code has a citizen advisory board made up of Beach Club members that comments on design and aesthetics. The approval authority in the code sits with the Village Council. Restrictive covenants may add rules of their own, so read them and ask the Village Clerk how the board's comment fits your project.
What wind speed are Sea Ranch Lakes windows designed for?
170 mph for a typical home. Sea Ranch Lakes is in Broward County, which is in the Florida Building Code's High-Velocity Hurricane Zone. Products must pass HVHZ impact testing, and each product's approval must cover the opening's size and design pressure. Lake and Intracoastal glass walls may need an engineer's numbers.
Is my Sea Ranch Lakes home in a flood zone?
Possibly. FEMA data we sampled in November 2026 showed Zone AE with base flood elevations of 6 to 7 feet on the west side near the lakes and Intracoastal, Zone X near the gate, and Zone VE at 11 feet on the beach parcel. Look up your own lot, since the village permit form asks for it.
Does the village have a rule on shutters or window style?
We found none that names a style, color or shutter type. The village code requires windows and doors in good working order with no boards or broken glass, and bars conditions that hurt the village's appearance. The Beach Club board's design comment and your restrictive covenants are where style questions come up.