Hurricane code · Deerfield Beach · Broward County
Which hurricane code applies to windows in Deerfield Beach?
Deerfield Beach is inside Broward County's High Velocity Hurricane Zone, so new or replacement windows and doors need a permit from the City Building Division and a product approval that is valid in the HVHZ: a Miami-Dade NOA or a Florida Product Approval. Roofs under 30 feet use the city's window and door checklist.
Last checked: November 3, 2026 · General information, not engineering or legal advice. Confirm requirements for your address with the building department.
Most Deerfield Beach homes were built before today's window rules
The median Deerfield Beach home was built in 1977, according to U.S. Census figures (American Community Survey 2023) reported by City-Stats. One other housing site gives 1978. Either way, the typical house or condo here is older than the 1994 South Florida Building Code changes and older than the Florida Building Code that began in 2002.
The same source counts 46,309 housing units. A median is only a middle point, so the Broward County property record for your address is what shows your own year built, and that date tells you which code era your windows come from.
Why every opening in Deerfield Beach falls under the HVHZ
The Florida Building Code, 8th Edition (2023), defines the High Velocity Hurricane Zone as Broward and Dade counties. Deerfield Beach is in Broward, so the HVHZ rules apply across the whole city. There is no inland exception.
Boca Raton sits across the Hillsboro Canal in Palm Beach County and is not in the HVHZ, so the canal is where the stricter glass rules stop.
The design wind speed for a typical home (Risk Category II) in Broward's HVHZ is 170 mph. That is a 3-second gust figure from Section 1620.2, not a forecast. The 8th Edition took effect December 31, 2023. The 9th Edition is scheduled for December 31, 2026, and permits applied for before then generally stay under the 8th.
ZIP codes and communities we can place with a source
We list only areas where we found a source. If your address is not here, the rules above still apply, because they are citywide.
| Area | ZIP | What to know |
|---|---|---|
| City Hall and Building Department | 33441 | The permit office is at 150 NE 2nd Avenue in this ZIP. Single-family, townhome and duplex jobs under 30 feet use the city's window and door checklist. |
| Century Village East | 33442 | A 55+ condominium community listed at about 8,508 units in two- to four-floor buildings between 1970 and 1995 (a real-estate directory, not an official count). Condo rules apply: association letter and a contractor are required. |
| Deer Creek area | 33442 | Addresses on Deer Creek Wildwood Lane carry this ZIP. Check whether your building is a condo, a townhome or a house, because the permit path changes. |
| Beachfront | not confirmed | Sea turtle lighting rules apply on the beach, which matters when choosing glass tint or film for beachfront units. |
The Deerfield Beach Building Division and its permit portal
The City of Deerfield Beach Building Division, under Building Services, handles plan review, permits and inspections. It is at City Hall, 150 NE 2nd Avenue, Deerfield Beach, FL 33441. Call the city's Building Services office for questions before you go. The form is the Broward County Uniform Building Permit Application, trade Building. City checklists carry a CAP Government header, which shows the city's building services run through a contracted provider.
Since December 15, 2025, new permit applications and plans can be sent through the city's Online Permit Submittal. In-person submittals are still accepted at City Hall. The city also has a Building Permit Status and Payments page and a Permit and Inspection Report page for looking up a permit.
What the city's door and window checklist asks you to submit
The Door/Window Replacement checklist covers a single-family home, townhome or duplex with a common roof height under 30 feet. In plain terms, the package comes down to these items.
- Product approvals. Each product needs a Florida Product Approval or a Miami-Dade Notice of Acceptance. Submit one file per approval, named by product type. In the HVHZ, check the approval's limits of use to confirm it is valid there.
- Floor plan. Show the location and size of every door and window, using the Broward County schedule. The city checks the 25% aggregate-area threshold against the existing openings.
- Design pressure. Use the Broward County Fenestration Wind Load Chart for buildings under 30 feet, or a sealed design. The city posts both the chart and the Uniform Retrofit Window and Door Schedule.
- Notice of Commencement. If the contract is above the state lien-law threshold, a recorded Notice of Commencement is filed before the first inspection.
- Inspections. Request an inspection by 3:00 PM for the next business day. Keep the approved permit package on site.
The 30-foot line and the Broward retrofit rule
Broward's Formal Interpretation #24 (8th Edition) governs window, door, garage door and shutter retrofits on detached one- and two-family homes and townhouses with a common roof height under 30 feet.
Above 30 feet, a generic chart is not enough. The building needs a signed and sealed design from a Florida engineer or architect that shows every opening and its pressure. The county chart itself stops at 30 feet. For a 10 square foot opening at 15 feet, the wall pressure is +38.1 psf, and the wall corner reaches -51.0 psf.
Condos, townhomes and HOAs: who must sign and who may work
Deerfield Beach has many condominiums, and the city's rules for them are firm. The Building Division says the Florida Building Code does not let a condo owner do work on their own unit. A state-qualified contractor must be hired, and the permit must be in hand before work starts. The city notes that using an unqualified contractor is a felony under Florida Statute 489.127(1)(f).
The owner-builder affidavit works only for owners who rely on the Florida Statute 489.103 exemption and accept the contractor's duties. The city says that route does not apply to condominiums or multi-family property.
Expect paperwork from your association. The city's shutter checklist asks for a formal HOA approval letter for condo and townhome projects, and the Building Services page says an HOA affidavit is needed for all residential permits. Ask your board for its window standards before you choose a frame color or style.
Broward's 25-year inspection and milestone inspections for older buildings
Many Deerfield Beach buildings are now past 30 or 40 years old. Broward's Building Safety Inspection Program requires structural and electrical inspection once a building is 25 years old, then every 10 years. That rule took effect on August 9, 2024, under BORA Policy 05-05, and it applies countywide. One- and two-family homes are exempt. The city enforces it as a Broward municipality.
Florida's milestone law, Statute 553.899, adds structural inspections for condo buildings of three or more habitable stories. It applies at 30 years from the certificate of occupancy, or 25 where local conditions such as salt water justify it. For the two- to four-floor buildings in Century Village East, it applies only to buildings reaching three habitable stories, and we have not confirmed which ones do.
Shutters instead of impact glass: the Deerfield Beach permit rule
Shutters are allowed in the HVHZ if the product passes the same impact criteria. In Deerfield Beach, installing or replacing shutters, residential or commercial, requires a building permit.
The package has the Uniform Permit Application, a shutter detail form and a site plan marking each shutter location. Add the Owner-Builder Affidavit if there is no contractor. Roofs over 30 feet need design wind loads signed, sealed and dated by a design professional.
Impact glass needs no deployment before a storm, while shutters need someone to close them. Both can satisfy opening protection.
Beach lighting, storm history and mitigation paperwork
Deerfield Beach adopted a sea turtle lighting ordinance in 2000 (Chapter 34, Article IV of the city code), listed by the state wildlife commission. The city says nesting season runs March 1 through October 31.
We found no Deerfield Beach-only wind readings. The closest official ones are from Pompano Beach to the south. In Hurricane Wilma (October 24, 2005) the National Weather Service recorded 83 mph sustained wind and a 98 mph gust there.
A wind mitigation inspection, form OIR-B1-1802, can document your opening protection for an insurer. Florida Statute 553.844 also requires opening protection when large permitted work is done on a high-value older home in a wind-borne debris region. Read the statute or ask the city before you plan that kind of job. Under the city fee schedule (Resolution 2024/202), work done without a permit is charged at double the permit fee.
Where Deerfield Beach sits next to its neighbors
The city borders Boca Raton to the north across the Hillsboro Canal, and Pompano Beach to the south. Only the Palm Beach County side is outside the HVHZ. If you are comparing a quote or a permit from a neighboring city, check the office and checklist that apply to your own address.
Send your measurements and your building type, and we can help you get a written quote that names the product approvals you will need on the permit. You can call (754) 303-7130.
Deerfield Beach questions
Do I need a permit to replace windows in Deerfield Beach?
Is Deerfield Beach in the HVHZ?
What wind speed are windows designed for in Deerfield Beach?
Can I use shutters instead of impact windows in Deerfield Beach?
Does my Deerfield Beach condo need association approval for new windows?
Does Deerfield Beach 40-year recertification cover windows?
Sources
- City of Deerfield Beach - Building Services
- City of Deerfield Beach - Door/Window Replacement checklist
- City of Deerfield Beach - Shutters checklist
- City of Deerfield Beach - Online Permit Submittal
- Broward BORA Formal Interpretation #24 (8th Edition)
- UpCodes - FBC 2023 Chapter 16
- Florida Senate - F.S. 553.899
- NWS Miami - Hurricane Wilma
- NWS Miami - Hurricane Irma
- City-Stats - Housing in Deerfield Beach
- Broward BORA Policy 05-05 amendments, effective Aug 9, 2024
- Broward BORA Building Safety Inspection Program brochure (2024)